| brand | ZKP/Zhongkepu |
|---|
I am honored to recommend it to youIntroduction to Analysis of 2,6-Dichlorobenzaldehyde,The 2,6-dichlorobenzaldehyde analysis gas chromatograph is one of the key research and development products of Tengzhou Zhongke Spectral Analysis Instrument Co., Ltd. If you have any needs or suggestions, please feel free to contact us,:We will be happy to serve you!
2,6-dichlorobenzaldehyde is an important dye intermediate, and our company mainly uses it to produce dye bleach B. Therefore, its inspection directly affects the production of the workshop. Previously, the company used liquid chromatography for the analysis of 2,6-M chlorobenzaldehyde entering the factory, with external standard method for quantification. However, it caused serious column pollution. Therefore, we conducted experiments using gas chromatography method for determination, using FID detector, OV-1 capillary column, and benzophenone as the internal standard. Through the investigation of sample density and recovery rate, we believe that this method is feasible
【 Instruments and reagents 】
Chromatograph host |
GC-2010Chromatograph(FID+capillary injection) |
1tower |
chromatographic column |
OV-1 capillary column 30m * 0.32m |
1branch |
data processing |
Chromatography workstation |
1cover |
External air source |
Hydrogen gas cylinder or generator |
1cover |
computer |
Brand Computerxpsystem |
1tower |
reagent |
Solvent: Toluene (analytical grade) Internal standard: Benzophenone (analytical grade) |
|
chromatogram

|
GC-2010Type gas chromatographDetailed information: 1.High cost performance ratio, complete dual air circuit design: can be installed simultaneouslyFID、TCD、FPDperhapsFID、TCD、ECDThree detectors can be installed simultaneously, including one packed column and one capillary column, as well as optional types such as dual capillary and dual amplifier. Choose from five detectors and methane converters, ceramic or quartz nozzles. 2.Adopting brand new doubleCPUDesign, original Japanese high integration electronic circuit technology,Excellent reliability and anti-interference ability,The precision of temperature control has reached0.1℃, with higher display accuracy0.01℃And it can simultaneously display the power consumption percentage of each heating part. Six channel temperature turbidity automatic alarm and automatic power-off protection function. Main technical specifications of the detector Hydrogen flame ionization detector(FID) (1)Cylindrical collection electrode structure design, quartz nozzle, responsive* (2)Detection limit:≤8×10g/s(HEXADECANE/isooctane) (3)Baseline noise:≤2×10A (4)Baseline drift:≤2×10A/30min (5)Linear:≥10 Thermal conductivity detector(TCD) (1)Adopting a semi diffusive structure (2)The power supply adopts constant current control mode (3)Sensitivity:≥2500mV·ml/mg(HEXADECANE/isooctane). (4)Baseline noise:≤20μV. (5)Baseline drift:≤100μV/30min. Note: External dimensions: 660 * 460 * 465mm, total weight of the machineQuantity: 60 kg Input power supply: AC 220V ± 10% 50HZ 2KW |
