Agilent 1100/1200 HPLC series liquid chromatography instrument
System Characteristics
1. We have a wide selection of 1100/1200 series pumps, injection systems, and detectors.
2. Easy to use EZ Chrom Elite Compact software
3. The system configuration is flexible and can use binary, ternary, and quaternary gradient high-performance liquid chromatography systems.
4. Professional software can achieve analysis, data storage, data stability, and regulatory adaptability, meeting regulatory requirements.
Parameters
Agilent 1100 Pump System Parameters
The capillary liquid phase pump system controlled by electronic flow control valve (EFC) has stable accuracy and flow rate range
Column flow velocity range:
1-20ul/min; 10-100ul/min (optional)
0.001-2.5m/min (EFC closed state)
High pressure preparation pump system, unit or dual high-pressure preparation pump
Flow rate range: 0.001-100m1/min
Analytical pump system
Flow rate range:
Unit pump: 0.001-10m3/min
Binary pump: 0.001-5m3/min
Four element pump: 0.001-10m3/min
Agilent 1100 series injection system with a complete range of varieties
Standard manual sampler (analytical or preparation type)
● Standard automatic sampler
Sample bottle capacity: up to 100 pieces (2mlx100)
Injection volume: 0.1-100ul (0.1-1800ul) optional
● Micro disc automatic sampler
Sample bottle capacity: 2x96 (orifice plate), 2x386 (orifice plate) or 100x2ml
Injection volume: 0.1-100ul (standard part)
0.1-1500ul optional
● Micro standard automatic sampler/micro disc automatic sampler
Injection volume: 0.01-8ul (standard); 0.01-40ul (optional)
● Constant temperature standard automatic sampler/micro disc automatic sampler
Temperature range: 4-40 ℃ with adjustable step size of 1 ℃
220 type microporous plate automatic sampler - combined chemical sample management system
Sample bottle capacity: up to 12 microplates (96 well plate, 384 well plate) for various specifications of test tubes
Injection volume: 0.1-5ul; 0.1-20ul
Agilent 1100 High Performance Liquid Chromatography Series Detector
Variable wavelength scanning ultraviolet detector (VWD)
Wavelength range: 190-600nm
● Multi wavelength detector (MWD)
Wavelength range: 190-950nm (dual light source)
● Diode Array Detector (DAD)
Wavelength range: 190-950nm (dual light source)
Fluorescence detector (FID)
Excitation wavelength: 200-700nm
Emission wavelength: 280-900nm
Spectral storage: Full spectrum
Differential Refraction Detector (RID)
Temperature control: Room temperature+5 ℃ to 55 ℃
Built in automatic purge valve and automatic solvent circulation valve
Electrochemical detector (ECD)
LC/MS Four Level Rod Mass Detector (MSD)
LC/MS ion trap mass detector (Trap MSD)
Column temperature box and deaerator components
● Column temperature box
Temperature range: 10 ℃ to 80 ℃ at room temperature
Optional: Column switching valve
● Agilent vacuum online deaerator