English

Qingdao Lubo Weiye Environmental Protection Technology Co., Ltd
Home>Products>American Huarui FGM-200X Organic Gas Detector (RAEGuard 2)
American Huarui FGM-200X Organic Gas Detector (RAEGuard 2)
Product Introduction: RAEGuard2PID is not only compatible with RAEGuardPID functions, but also has significant improvements in both internal and exter
Product details
  • Product Introduction

    RAEGuard2 PID is not only compatible with the functions of RAEGuard PID, but also has significant improvements in both internal and external performance. It is an organic gas detector with a flameproof host, intrinsic safety sensor, and fixed installation method. It can be widely applied in fields such as petroleum, petrochemicals, metallurgy, chemical engineering, environmental protection, papermaking, printing and dyeing, municipal engineering, scientific research, education, and national defense.

    Product Features:

    Leading the global trend of PID development, we adopt independently developed third-generation intrinsic safety PID sensors with multiple international patents, which have faster response time, stronger moisture resistance, and the largest measurement range in the industry; Sensor interchangeability without the need for tools, supporting offline calibration

    Self cleaning patented technology ensures long-term stable operation of instruments and extends the service life of sensors

    Unique pump suction sampling with built-in powerful sampling pump, wide monitoring range, short response and recovery time, giving the instrument a keen sense of smell

    Ultra wide measurement range, freely adjustable range, measurement accuracy reaches ppb level

    The 3G open gas path structure expands the detection range by 2 times, accelerates response time by 10 seconds, and effectively extends maintenance free time

    Intelligent temperature and zero compensation algorithms enable instruments to exhibit superior performance

    Can detect thousands of gases with broad-spectrum detection, built-in gas storage, convenient for users to choose

    Multiple signal outputs can be fine tuned to standard 4-20mA (three wire system) RS485 Modbus、 Three level switch output (normally open/normally closed optional)

    A friendly human-machine interface with a large dot matrix LCD display, supporting both Chinese and English interfaces; No need to open the cover, magnetic rod operation, single person maintenance; Local alarm indication, integrated sound and light alarm (optional)

    Stainless steel casing can be applied to extremely complex and harsh working environments

    International certification through ATEX, UL, CSA and other certifications, with international high-end quality

    Product Specifications


    Detection Principle

    Photoionization

    sensor

    Smart Sensor

    sampling method

    Pump suction/diffusion type

    range

    0~100ppm; 0~1000ppm
    (Users can freely set)

    working power supply

    10~28VDC

    maximum power

    210mA@24VDC

    output signal

    4~20mA, fine-tunable

    Load impedance

    600Ω

    detection accuracy

    ±3%F.S.

    Response time (T90)

    <>

    Protection level

    IP65

    electrical interface

    3/4&rdquo; NPT M

    Installation method

    2&rdquo; Vertical pipe/wall mounted installation

    Other outputs

    RS485 Modbus; Third level passive relay 30VDC 2A, normally open/normally closed optional

    ambient temperature

    -40℃~+55℃

    ambient humidity

    0~95% RH (no condensation)

    environmental stress

    90kPa to 110kPa

    display mode

    128 × 64 dot matrix LCD, supporting graphic and text display

    Overall dimensions

    257mm×201mm×107mm(HWD)

    Shell material

    stainless steel

    weight

    3.5kg

    ATEX

    Host: Ex d [ia Ga] IIC T4 Gb
    Intelligent sensors: Ex ia IIC T4; Ex ia I

    IECEx

    Host: Ex d [ia Ga] IIC T4 Gb
    Intelligent sensors: Ex ia IIC T4, Ga; Ex ia I

    Explosion-proof certification

    Host: Ex d [ia] IIC T4
    Intelligent sensor: Ex ia IIC T4



    Product Selection

    Order Number

    model

    gas

    Standard range

    remark

    D03-0001-C00

    FGM-2001

    VOC

    0-100ppm

    diffusion

    D03-0002-C00

    FGM-2002

    VOC

    0-1000ppm

    diffusion

    D03-0004-C00

    FGM-2001

    VOC

    0-100ppm

    Flow through

    D03-0005-C00

    FGM-2002

    VOC

    0-1000ppm

    Flow through

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!