TPG-3030 Total Phosphorus Online Automatic Analyzer This product is easy to detect, and the sample to be tested does not require any pre-treatment. Si
Product details
This product has simple testing,The test sample does not require any pre-treatment. Simply insert the water sample lifting tube into the system water sample to measure the total phosphorus concentration. The device has a large measurement range of0.1~500mg/L TP, This method is mainly used for online automatic monitoring of total phosphorus concentration in point sources of wastewater discharge and surface water.
Key Features:
·Unique design enables this product to have lower failure rates, lower maintenance requirements, lower reagent consumption, and higher cost-effectiveness compared to similar products;
·Select valve component: Select reagent sampling timing sequence;
·Measurement component: Accurate measurement of reagents is achieved through a visual photoelectric system, overcoming quantitative errors caused by wear of peristaltic pump tubes; At the same time, precise quantification of trace reagents has been achieved, with each dose being only 1.5 milliliters, greatly reducing the amount of reagents used;
·Sample injection component: peristaltic pump negative pressure suction, there is always an air buffer zone between the reagent and the pump tube to avoid corrosion of the pump tube;
·Sealed digestion component: High temperature and high pressure digestion system accelerates the reaction process and overcomes the corrosion of equipment caused by the volatilization of corrosive gases in open systems;
·Reagent tube: Imported new type of transparent polytetrafluoroethylene hose with a diameter greater than 1.5mm is used to reduce the probability of particle blockage in water samples.
Technical Indicators:
Method basis: National standardsGB11893-89 "Water quality - Determination of total phosphorus - Ammonium molybdate spectrophotometric method";
Measurement range:0-500mg/L total phosphorus (graded 0-2mg/L); 0.1-10mg/L; 0.5-50mg/L;
1-100mg/L; 5-500mg/L).
Indication error: ≤0.5mg/L:±0.05mg/L; >0.5mg/L:±10%;
heavy again Sex: not exceed±5%;
stable fixed Sex: Not exceeding ± 10% within 24 hours;
Measurement cycle: *The small measurement cycle is30 minutes, color development time can be freely modified within 5-120 minutes;
Sampling period: Time interval(10~9999min adjustable) and whole point measurement mode;
Calibration cycle:Adjustable at any interval and time from 1 to 99 days;
lose Out:4~20mA(2路) RS232、RS485;
Environmental requirements: Indoor temperature adjustable, recommended temperature+5~28℃; Humidity ≤ 90% (non condensing);
electricity Source: AC220±10% V,50±10% Hz,5 A;
ruler Inch: tall1570 x width 500 x depth 450 mm;
its He: Abnormal alarms and power outages will not result in data loss;Touch screen display and command input;
After abnormal reset and power failure, the instrument will automatically discharge residual reactants from the instrument and restore its working state.
Stable quality: Implement full process quality monitoring, meticulous and all-round testing!
Reasonable price: Efficient internal cost control reduces expenses and benefits customers!
Fast delivery: advanced production line, sufficient stock, shortened delivery time!