MKA-610 has been discontinued, alternative model: MKV-710M
Capacity Karl Fischer Moisture Analyzer MKV-710M
Dual channel volumetric Karl Fischer moisture analyzer MKA-610
The main features of the dual channel volumetric Karl Fischer moisture analyzer MKA-610 are:
1. It can connect two measuring units and perform titration function simultaneously.
2. Adopting touch screen operation, touch screen image input control.
3. The touch unit and measurement unit can be set separately.
4. Adopting an eight inch color LCD display, the titration curve is displayed in real-time.
5. Connect the ADP-611 heating furnace and automatically scan the heating temperature.
6. Use micro memory cards (CF) for data storage.
The suction and discharge mechanism of the reagent is a standard accessory.
8. There is no need to change their individual settings due to changes in solvents or samples.
9. Fully comply with GLP/GMP functions.
Technical parameters of dual channel capacity Karl Fischer moisture analyzer MKA-610:
Measurement method: Karl Fischer titration method.
Measurement range: Titration amount: 0.005-99.995mL, moisture content: 0.1-500mg H2O, moisture content: 10ppm~100% H2O.
Burette: Capacity: 10mL burette, precision: ± 0.015mL, repeatability: ± 0.005mL.
Resolution of burette: 1/20000.
Endpoint detection method: Use dual platinum electrodes to detect polarization potential.
Endpoint determination method: If the duration of the polarized potential is within the specified range, it is determined as the endpoint.
The setting range for endpoint judgment time is 1 to 99 seconds.
Control operation: Input settings directly on the touch screen.
Display function: Eight inch color LCD display, 256 colors, 800 × 600 light points.
Calculation function: Moisture content calculation, statistical calculation processing (mean, standard deviation, relative standard deviation).
Other special uses: automatic reagent suction and discharge, drift automatic correction, automatic measurement startup, 10 sets of blank and titration data.
GLP support functions: detection of standard substances, titration calibration of reagents, and registration of operator names.
Solvent demand: 30-100mL, when using an S-shaped titration cell.
Usage environment: Temperature: 5-35 ° C, relative humidity: Below 85% RH.
Power Supply: AC100~120/200~240V ± 10%, 50Hz/60Hz.
Power: Main Touch Unit (MCU-610): Approximately 20W, measuring unit (MKA-610) and mixer: approximately 30W.
MKA-610-ST: A set of burettes for positive titration.
MKA-610-TT:Two sets of burettes, positive titration, reverse titration, and automatic titration calibration.