1、 Technical performance and indicators:
1The range of elemental analysis ranges from sodium (Na) to uranium (U);
2、 The range of element content analysis is from 1PPm to 99.99%;
3Measurement time: 100-300 seconds (adjustable);
4、 The detection limit for harmful elements (limited to Cd/Pb/Cr/Hg/Br/Cl) specified in the RoHS directive is up to 1PPM;
5、The energy resolution is129± 5 electron volts;
6The temperature adaptation range is 15 ℃ to 30 ℃;
7、Power supply: AC220V±5V(It is recommended to configure an AC purification stabilized power supply);
8Working conditions: Working temperature:15-30℃ Relative humidity:40%~70%Electricity Source:AC :220V±5V.
IIProduct Features
1TheEDX 8000HEquipped with a vacuum testing system, expanded the range of element testing, and equipped with detectorsSDDThe testing system detects various elements between ores to reduce interference between elements
2Overall structured design, the instrument is aesthetically pleasing and elegant.
3Adopting the new American modelSDDSilicon driftDetector, electrically cooled instead of liquid nitrogen cooled, with small size, accurate data analysis, and low maintenance cost.
4Adopting research and developmentSESThe signal processing system (digital multi-channel) effectively improves the peak to background ratio, making measurements more accurate.
5One click automatic testing, simpler and more convenient to use, with a more user-friendly interface.
6Seven types of optical path calibration and collimation systems, automatically switching according to different samples.
7Multiple anti radiation leakage design.
8Optimize the integrated heat dissipation design to greatly improve the overall heat dissipation performance of the machine, ensuringXSafe operation of radiation sources.
9The temperature monitoring technology of the movement ensures the safe and reliable operation of the radiation source, effectively extending its service life and reducing usage costs.
10Multiple instrument accessory protection system, and can be monitored throughout the entire process through software,Make the instrument work more stably and safely.
11Specialized vacuum testing software, whether to vacuum or not can be freely selected, real-time display of vacuum degree, standard window design, user-friendly interface, easy operation, all controls are within a click of the mouse.
12This machine adoptsUSB2.0Interface, effectively ensuring accurate, high-speed, and efficient transmission of data.
13Fully automatic vacuum system,Thoroughly shielding the impact of air on light element testing,Greatly improved the detection limit of light elements, while also expanding the detection range.
14The integrated vacuum chamber design effectively ensures the vacuum degree that meets the testing requirements, while improving the maintainability of the equipment.
15The conversion between vacuum testing and non vacuum testing is simple and convenient for customers to use; Simultaneously opening the lid releases the vacuum, which is safe, simple, and practical.
3、 Main hardware configuration of the instrument
1TheSDDElectric refrigeration detector:
(1)TheSDDElectric refrigeration detector; Resolution:129±5eelectron volt
(2)TheAmplification circuit module:Regarding the characteristics of the sampleXRadiation detection; Collect information through detection,Further enlarge.
2TheXX-ray excitation device:
(1)The Filament current output:1mA;
(2)TheBelongs to semi consumable components with a service life greater than5000hour
3、 High voltage launch device:
(1)TheVoltage output:50kV;
(2、 )minimum5kvControllable adjustment
(3、 )Equipped with voltage overload protection
4Integrated vacuum system
(1)TheA vacuum pump system with excellent performance such as low vibration, low noise, self-protection, and fast pumping speed;
(2)TheGeometric pumping speed:60 L/min(50Hz)
(3)、extreme pressure:6.7×10-2Pa
5Digital Multi Channel Analyzer:
(1)Convert the collected analog signals into digital signals,And provide the processing results to the upper computer software;
(2)TheNumber of lanes: 4096;
(3)The Includes signal enhancement processing function;
6、Optical path filtering module
(1)The reduceXInterference during the transmission process of the ray path ensures accurate signal reception by the detector;
(2)The Integrate the collimator with the filter;
7、 Collimator automatic switching module
(1)Up to7The selection and caliber are respectively8-1#, 8-2#, 8-3#, 8-4#,6#, four#, two#.
8、 Filter automatic switching module
(1)TheFree selection and switching of five types of filters.
9、Free combination module of collimator and filter
(1) 、Up to dozens of collimators and filters can be freely combined.
10、Automatic selection module for work curve
10、 Automatic selection of work curve, eliminating manual selection, avoiding human operation errors, automation and intelligence
Make the operation more humane and convenient.
4 Specialized software
1、Software Introduction
Specially developed for detecting the elemental composition of metal materials (including vacuum control function), the collected spectral signals are processed, calculated, and the measurement results are reported and displayed.
2、Feature Introduction
※ Adjustable data for different mineral materials, with a measurement time of100-300Seconds (adjustable)
The operation interface is simple and intuitive, easy to use, and does not require professional operation
3The software interface is shown in the following figure:

※ Suitable calibration curves can be automatically selected for easier and more accurate measurement
The interface automatically switches between Chinese and English, and has a third-party language customization function
※ Automatic calibration instrument
※ Comes with sample material qualitative analysis to prevent manual users from selecting the wrong curve
※ Multiple report formats for printing
※ Multiple spectrograms can be displayed simultaneously
Real time display of instrument testing parameters and vacuum degree, all control is clear at a glance
※Movement temperature monitoring technology ensuresXThe safe and reliable operation of the radiation source effectively extends its service life and reduces usage costs.
4、 Sample configuration
Standard samples are used to create working curves
1、 Sample cavity:
(1)Open sample cavity:610mm×320mm×100×
(2)Semi closed sample chamber (during vacuum pumping):Φ100mm×h75mm
2、reference material : Silver correction film
5、 Standard attachments
Low noise fast pumping vacuum pump
※ Small size, light weight, simple structure, easy to maintain and repair
※ Fast pumping speed,20SIt can meet the requirements of vacuum testing
The maximum pressure can reach6.7×10-2Pa
※ Single phaseAC220VPower supply, no need for external three-phase power
6、 Application areas:
1.ROHS/Zero halogen detection instruction
2.In the field of alloy analysis (Especially light elements)
Composition analysis of zinc aluminum alloy
Analysis of Aluminum Alloy Composition
Copper alloy gold medal number determination and composition analysis
Stainless steel composition analysis (vacuum light element detection)
Composition analysis of cast iron wait
3 .Analysis of Coating Composition
film analysis
Environmental protection testing of coating
4.Packaging instruction detection standard(94/62/EC)
CD+PB+Hg+ Cr6<100
5.Toy Directive Testing Standards
6.Analysis of Mineral Composition and Items
7Warranty and after- sale service
1To the clientOperators receive free training.
2、 domestic clientsInstallation, debugging, acceptance, training, and technical services are all provided free of charge at the user's site to train operators. (Foreign customers can negotiate to resolve)
3、Under normal use, if the malfunction is confirmed by the technical personnel of our after-sales service department to be caused by process or material defects and has not been disassembled or repaired, the instrument host will be covered by a one-year warranty from the date of acceptance.
4、productlifetime maintenance(Customer)Detailed and authentic valid purchase vouchers and warranty cards must be provided.
5、Free software upgrades are provided.
6、Provide the most effective technical services, after receiving user fault information,3Response within hours, if necessary,48Send someone to come and repair and troubleshoot within hours