VIP member
EJA310 Absolute Pressure Transmitter
EJA310A absolute pressure transmitter Yokogawa EJA310A absolute pressure transmitter is used to measure the pressure of gases, liquids, and vapors, an
Product details
EJA310A Absolute Pressure Transmitter
YokogawaEJAThe 310A absolute pressure transmitter is used to measure the pressure of gases, liquids, and vapors, and then convert it into a 4-20mADC current signal output. The Yokogawa EJA310A pressure transmitter can also communicate with each other through the BRAN controller, CENTUM CS/μ XL, or Rosemount HART475 controller for setting and monitoring.
Specification of EJA310A
| EJA310A Absolute Pressure Transmitter | ||||
| L membrane box | M membrane box | A membrane box | ||
| measurement range | 0~10kPa abs (0~2.95inHg abs) |
0~130kPa abs (0~38inHg abs) |
0~3MPa (0~430psia) |
|
| Measurement range | 0.67~10kPa (0.2~2.95inHg) |
1.3~130kPa (0.38~38inHg) |
0.03~3MPa (4.3~430psi) |
|
| precision | ±0.2% | ±0.15% | ±0.15% | |
| Protection level | IP67,NEMA 4X, And JIS C0920 immersion proof type | |||
| Explosion proof specifications | FM,CENELEC ATEX,CSA,IECEx | |||
| output signal | 4~20mA DC or FOUNDATION fieldbus or PROFIBUS PA two-wire digital communication | |||
| power supply | BRAN and HART: 10.5~42V DC (intrinsic safety type: 10.5~30V DC) Fieldbus: 9~32V DC (Intrinsic Safety Entity Mode 9~24V DC, Intrinsic Safety FISCO Mode 9~17.5V DC) |
|||
| ambient temperature | -40-85 ℃ (-40~185 ℉) (ordinary type) -30~80 ℃ (-22~176 ℉) (with built-in indicator) |
|||
| process temperature | M and A membrane box: -40~120 ℃ (-40~248 ℉) (ordinary type) L film box: -40~100 ℃ (-40~212 ℉) (ordinary type) |
|||
| Maximum overvoltage | 500kPa abs (72psia) |
500kPa abs (72psia) |
4.5MPa abs (645psia) |
|
| install | 2-inch pipe installation | |||
| Material of liquid receiving components | Capsule | SUS316L (diaphragm: Hastelloy C-276) | ||
| Container flange | SUS316 | |||
| shell | Aluminum alloy or SUS316 stainless steel (optional) | |||
EJA310A - Selection Table
Basic specification code: EJA310A-DMS5A-92NN
| Item 1: Output signal |
|
||||||||||||||||
| Item 2: Measurement range (membrane box) |
|
||||||||||||||||
| Item 3: Material of liquid receiving parts |
|
||||||||||||||||
| Item 4: Process Interface |
|
||||||||||||||||
| Item 5: Material of bolts and nuts |
|
||||||||||||||||
| Item 6: Installation Method |
|
||||||||||||||||
| Item 7: Electrical Interface |
|
||||||||||||||||
| Item 8: Hidden Display Table |
|
||||||||||||||||
| Item 9: Installing the bracket |
|
Online inquiry