YokogawaEJAThe 510A absolute pressure transmitter and Yokogawa EJA530A pressure transmitter are used to measure the pressure of gases, liquids, and vapors, and then convert them into 4-20mADC current signals for output. The Yokogawa EJA510A pressure transmitter and Yokogawa EJA530A pressure transmitter can also communicate with each other through the BRAN controller, CENTUM CS/μ XL, or Rosemount HART 475 controller for setting and monitoring.
Specification of EJA510A/530A
| EJA510A/EJA530A direct installation absolute pressure and pressure transmitter (The following measurement results are all data from EJA510A) |
|||||
| A membrane box | B membrane box | C membrane box | D membrane box | ||
| measurement range | 0~200kPa (0~29psi) |
0~2MPa (0~290psi) |
0~10MPa (0~1450psi) |
0~50MPa (0~7200psi) |
|
| Measurement range | 10~200kPa (1.45~29psi) |
0.1~2MPa (14.5~290psi) |
0.5~10MPa (72.5~1450psi) |
5~50MPa (720~7200psi) |
|
| precision | ±0.2% | ±0.2% | ±0.2% | ±0.2% | |
| Protection level | IP67,NEMA 4X, And JIS C0920 immersion proof type | ||||
| Explosion proof specifications | FM,CENELEC ATEX,CSA,IECEx | ||||
| output signal | 4~20mA DC or FOUNDATION? Fieldbus or PROFIBUS PA two-wire digital communication | ||||
| power supply | BRAN and HART: 10.5~42V DC (intrinsic safety type: 10.5~30V DC) Fieldbus: 9~32V DC (Intrinsic Safety Entity Mode 9~24V DC, Intrinsic Safety FISCO Mode 9~17.5V DC) |
||||
| ambient temperature | -40-85 ℃ (-40~185 ℉) (ordinary type) -30~80 ℃ (-22~176 ℉) (with built-in indicator) |
||||
| process temperature | -40-120 ℃ (-40~248 ℉) (ordinary type) | ||||
| Maximum overvoltage | 4MPa (580psi) |
4MPa (580psi) |
20MPa (2900psi) |
60MPa (8500psi) |
|
| install | Direct installation/2-inch pipe installation | ||||
| Material of liquid receiving components | Capsule | Hastelloy C-276 | |||
| Process connector | SUS316L, Hastelloy C-276 | ||||
| shell | Aluminum alloy or SUS316 stainless steel (optional) | ||||
EJA510A/530A Selection Table
| Item 1: Output signal |
|
||||||||||||||||
| Item 2: Measurement range (membrane box) |
|
||||||||||||||||
| Item 3: Material of liquid receiving parts |
|
||||||||||||||||
| Item 4: Process Interface |
|
||||||||||||||||
| Item 5:- |
|
||||||||||||||||
| Item 6:- |
|
||||||||||||||||
| Item 7: Electrical Interface |
|
||||||||||||||||
| Item 8: Hidden Display Table |
|
||||||||||||||||
| Item 9: Installing the bracket |
|