EVA film UV aging test chamber
Reference standard for UV aging test of EVA film IEC61215:2005、IEC61646:2008、IEC61345:1998、ASTM D4329、D499、D4587、D5208、G154、G53; ISO 4892-3、ISO 11507;
Product details
YPV-UV-EVA EVAUV aging test chamber for adhesive film
Reference standards
IEC61215:2005、IEC61646:2008、IEC61345:1998、ASTM D4329、D499、D4587、D5208、G154、G53; ISO 4892-3、ISO 11507; EN 534; prEN 1062-4、 BS 2782; JIS D0205; SAE J2020 and other testing standards. This standard is equivalent to IEC 61345:1998 "Ultraviolet (PV) Test for Photovoltaic Modules".
Technical indicators
1. Studio size: 450 × 1170 × 500mm;
2. Dimensions: 580 × 1280 × 1450mm;
3. Temperature range: RT+10 ℃~70 ℃;
4. Humidity range: 90-98% R · H;
5. Humidity uniformity: ± 2%;
6. Temperature uniformity: ± 2 ℃;
7. Temperature fluctuation: ± 0.5 ℃;
8. Humidity fluctuation: ± 2%;
9. Temperature control method: PID self-tuning temperature control method;
10. Center distance of the lamp: 70mm;
11. Distance between sample and lamp center: 50mm;
12. Standard specimen size: 75 × 150mm or 75 × 300mm (special specifications need to be specified in the contract);
13. Water depth requirement for the sink: 25mm, automatic control;
14. Effective irradiation area: 900 × 210mm;
15. Ultraviolet wavelength: UV-A wavelength range is 315-400nm; UV-B wavelength range is 280-315nm;
16. Test time: adjustable from 0 to 999H;
17. Blackboard temperature: 40 ℃~65 ℃;
18. UV light and condensation time can be alternately adjusted;
Box structure
1. Material of the box shell: SUS stainless steel plate with spray coating treatment;
2. Inner liner material: SUS stainless steel plate;
3. Box cover material: SUS stainless steel plate with spray coating treatment;
Install a total of 8 UV-A or UV-B ultraviolet lamps on both sides of the studio;
5. The heating method is the inner pot sink type heating, which heats up quickly and has a uniform temperature distribution;
6. The box cover is a double-sided flip cover, which can be easily opened and closed;
7. The inner tank water level automatically replenishes to prevent the heating tube from burning out and being damaged;
8. The sample holder is made of stainless steel or aluminum alloy;
9. The bottom of the test chamber adopts high-quality fixed PU movable wheels;
10. The drainage system uses vortex and U-shaped sedimentation devices for drainage;
11. The surface of the sample is parallel to the plane of the ultraviolet lamp;
12. The spray type equipment is equipped with automatic nozzles inside, and the water pressure can be adjusted;
13. If the lamp is on and the door of the box is opened, the machine will automatically cut off the power supply to the lamp and enter a balanced state for cooling to prevent harm to the human body;
14. Over temperature protection inside the box. When the temperature inside the box is too high, the machine will automatically cut off the power and enter a balanced state for cooling.
Circuit control system
1. Japanese RKC temperature controller, with a control accuracy of ± 0.1 ℃;
2. Thin film KEY BOARD button;
3. Temperature control adopts P.I.D+S.S.R, and the system coordinates control with the same channel, which can improve the stability and service life of control components and interfaces;
4. Touch sensitive settings, digital and direct display;
5. It has the function of automatic calculation of P. I. D, which can reduce the inconvenience caused by manual setting;
6. Lighting and condensation can be independently controlled or alternately controlled in a cyclic manner;
7. The independent control time and alternating cycle control time for lighting and condensation can be set arbitrarily within one thousand hours;
8. In operation or setting, if an error occurs, a warning signal will be provided;
9. Schneider components from France;
10. Philips rectifier and starter (ensuring that the UV light can be turned on every time it is turned on);
Protection system
1. Non fuse protection switch;
2. Overtemperature;
3. Low water level;
4. Overload;
5. Leakage;
6. Fully sheathed terminal block;
7. Protection such as automatic shutdown;
Temperature control
UV cycle
The first-order photochemical reaction is not sensitive to temperature changes. However, the speed of the subsequent secondary reaction is closely related to temperature changes. Generally speaking, as the temperature increases, the reaction rate will accelerate. Therefore, temperature control is crucial during UV exposure testing, and it is even more important to match the test temperature used for accelerated testing with the highest temperature encountered by the material in practical applications. The temperature setting of UV in the device can be any point from 50 ℃ to 80 ℃, depending on the level of illumination and indoor ambient temperature. The temperature regulation of the equipment is controlled by a controller with microcomputer calculation function to command a series of systems inside the equipment, such as air heaters, water heaters, etc.
Moisture cycle
As the temperature increases, the destructive power of moisture on materials will sharply increase. Therefore, temperature control is the most basic requirement during wet exposure. Furthermore, to achieve an acceleration effect, it is necessary to maintain a high temperature environment during the wet exposure process. The temperature setting for the condensation process in the device can be any point from 40 ℃ to 60 ℃.
Heating system
1. Use U-shaped titanium alloy high-speed heating electric heating tube;
2. Temperature control and lighting are completely independent systems;
3. The temperature control output power is calculated by a microcomputer to achieve high-precision and high-efficiency electricity efficiency;
4. Equipped with anti overheating function of heating system;
The temperature of the black aluminum plate is controlled by a Japanese made RKC series temperature controller for heating, and the output power is calculated by a microcomputer with PID self-tuning. The monitoring adopts standard Pt-100 blackboard temperature sensor;
The temperature of the sink is also controlled by a Japanese made RKC series temperature controller for heating. The sink is located at the bottom of the box and is equipped with an electric water heater. During the cyclic testing process, there is a testing section called the dark condensation process, which requires the box to generate saturated water vapor at a relatively high temperature. When the water vapor encounters a relatively cold surface of the sample, it will condense on the surface of the sample.