Economic ammonia nitrogen measuring instrumentAmmolyt plus
feature
-
No need to fill electrolyte and replace ion membrane
-
Automatically compensate for the impact of interfering ions
-
On site continuous monitoring sensor technology
-
Quick response, no lag time
-
Automatic monitoring of biochemical treatment process
-
Multi directional monitoring of nitrogen removal process throughout the entire process
-
Very economical and practical
-
No need for calibration, good long-term stability
-
No reagent consumption, low investment and maintenance costs
Calibration free testing
After installing the corresponding ion electrode, the economical ammonia nitrogen measuring instrumentAmmolyt plusIt can be tested immediately without calibration. If the requirements are strict, an economical ammonia nitrogen measuring instrumentAmmolyt plusJust perform 'on-site water sample calibration', it's very simple, the sensor doesn't need to be taken out of the water sample. Users only need to compare with the laboratory photometry method at regular intervals, and if there is any deviation, then perform "on-site water sample calibration". In addition to on-site water sample calibration, standard solutions can also be selected2Point correction (note: usually not required). Through calibration, the system automatically evaluates the performance of various electrodes2Individual performance indicators, namely drift potential and slope. If this2If the indicators fall within the permitted range, it indicates that the correction is successful.
Technical Specifications
|
model |
AmmoLyt Plus 700IQ |
|
measurement parameters |
Ammonia nitrogen measurement |
|
Measuring principle |
Use reference electrode and ion selective electrode for potential measurement;Built in microprocessor, two core shielded cable containing power and data transmission |
|
Test range/resolution |
NH4-N: 1…2,000mg/l / 1mg/l, 0.1…100mg/l / 0.1mg/l |
|
Compensation method |
Automatic (installation of corresponding ion electrodes) or manual compensation |
|
Temperature test |
built-inNTCTemperature probe, range:0℃…+40℃ |
|
temperature compensation |
automatic compensation0℃…+40℃ |
|
Correction method |
Standard liquid2Point calibration or on-site actual water sample calibration(commonly used) |
|
Surrounding conditions |
Operating temperature:0℃…+40℃,Storage temperature:0℃…+40℃ |
|
pHscope |
pH 4 … pH 8.5 |
|
accuracy |
±5%Test value or±0.2 mg/lStandard liquid |
|
working life |
18month(Data obtained from testing in a sewage treatment plant environment) |