FL flat transformer
FL flat transformer
Product details
FL
Flat Transformer
Mold, PRI 2 x 115 Vac, SEC 2 x 5 – 2 x 24 Vac , 2 – 52 VA


General data
Measure the output voltage of 2 x 5-2 x 24 Vac
The maximum ambient temperature is 40 ° C
Measure power 2-52 VA
Insulation material grade E
Measure input voltage 2 x 115 Vac
Protection level IP 00
Validity up to 81%


advantage
Suitable for series or parallel dual input voltage
Low structural height
Suitable for series or parallel dual output voltage
Durable corrosion protection, high insulation value, and extremely high electrical reliability brought by the use of mold resin mold XtraDenseFill
Self extinguishing mold material
Ensure minimum specifications at high power


standard
The protection transformer complies with VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6, UL 5085-1/-2, CSA 22.2 No.66
Isolation transformers comply with: VDE 0570 Parts 2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4, UL 5085-1/-2, CSA 22.2 No.66
The protection transformer complies with VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6, UL 5085-1/-2, CSA 22.2 No.66


license
VDE, UL 5085-1/-2, CSA 22.2 No.66


application
As a power transformer used for matching voltage and simple electrical isolation.
As an isolation transformer used for safe electrical isolation of input and output terminals. This transformer is suitable for the construction of protective isolation devices and protective measures that comply with VDE 0100 requirements.
As a protective transformer used for safe electrical isolation of input and output terminals. By limiting the output voltage, this transformer is suitable for circuit construction of SELV and PELV.

variant Measure input voltage Measure output voltage measured power
FL 2/5 2 x 115 Vac 2 x 5 Vac 2 VA
FL 2/6 2 x 115 Vac 2 x 6 Vac 2 VA
FL 2/8 2 x 115 Vac 2 x 8 Vac 2 VA
FL 2/9 2 x 115 Vac 2 x 9 Vac 2 VA
FL 2/12 2 x 115 Vac 2 x 12 Vac 2 VA
FL 2/15 2 x 115 Vac 2 x 15 Vac 2 VA
FL 2/24 2 x 115 Vac 2 x 24 Vac 2 VA
FL 4/6 2 x 115 Vac 2 x 6 Vac 4 VA
FL 4/8 2 x 115 Vac 2 x 8 Vac 4 VA
FL 4/9 2 x 115 Vac 2 x 9 Vac 4 VA
FL 4/12 2 x 115 Vac 2 x 12 Vac 4 VA
FL 4/15 2 x 115 Vac 2 x 15 Vac 4 VA
FL 4/18 2 x 115 Vac 2 x 18 Vac 4 VA
FL 4/24 2 x 115 Vac 2 x 24 Vac 4 VA
FL 6/5 2 x 115 Vac 2 x 5 Vac 6 VA
FL 6/6 2 x 115 Vac 2 x 6 Vac 6 VA
FL 6/8 2 x 115 Vac 2 x 8 Vac 6 VA
FL 6/9 2 x 115 Vac 2 x 9 Vac 6 VA
FL 6/12 2 x 115 Vac 2 x 12 Vac 6 VA
FL 6/15 2 x 115 Vac 2 x 15 Vac 6 VA
FL 6/18 2 x 115 Vac 2 x 18 Vac 6 VA
FL 6/24 2 x 115 Vac 2 x 24 Vac 6 VA
FL 8/6 2 x 115 Vac 2 x 6 Vac 8 VA
FL 8/8 2 x 115 Vac 2 x 8 Vac 8 VA
FL 8/9 2 x 115 Vac 2 x 9 Vac 8 VA
FL 8/12 2 x 115 Vac 2 x 12 Vac 8 VA
FL 8/15 2 x 115 Vac 2 x 15 Vac 8 VA
FL 8/18 2 x 115 Vac 2 x 18 Vac 8 VA
FL 8/24 2 x 115 Vac 2 x 24 Vac 8 VA
FL 10/5 2 x 115 Vac 2 x 5 Vac 10 VA
FL 10/6 2 x 115 Vac 2 x 6 Vac 10 VA
FL 10/8 2 x 115 Vac 2 x 8 Vac 10 VA
FL 10/9 2 x 115 Vac 2 x 9 Vac 10 VA
FL 10/12 2 x 115 Vac 2 x 12 Vac 10 VA
FL 10/15 2 x 115 Vac 2 x 15 Vac 10 VA
FL 10/18 2 x 115 Vac 2 x 18 Vac 10 VA
FL 10/24 2 x 115 Vac 2 x 24 Vac 10 VA
FL 14/5 2 x 115 Vac 2 x 5 Vac 14 VA
FL 14/6 2 x 115 Vac 2 x 6 Vac 14 VA
FL 14/8 2 x 115 Vac 2 x 8 Vac 14 VA
FL 14/9 2 x 115 Vac 2 x 9 Vac 14 VA
FL 14/12 2 x 115 Vac 2 x 12 Vac 14 VA
FL 14/15 2 x 115 Vac 2 x 15 Vac 14 VA
FL 14/18 2 x 115 Vac 2 x 18 Vac 14 VA
FL 14/24 2 x 115 Vac 2 x 24 Vac 14 VA
FL 18/5 2 x 115 Vac 2 x 5 Vac 18 VA
FL 18/6 2 x 115 Vac 2 x 6 Vac 18 VA
FL 18/8 2 x 115 Vac 2 x 8 Vac 18 VA
FL 18/9 2 x 115 Vac 2 x 9 Vac 18 VA
FL 18/12 2 x 115 Vac 2 x 12 Vac 18 VA
FL 18/15 2 x 115 Vac 2 x 15 Vac 18 VA
FL 18/18 2 x 115 Vac 2 x 18 Vac 18 VA
FL 18/24 2 x 115 Vac 2 x 24 Vac 18 VA
FL 24/5 2 x 115 Vac 2 x 5 Vac 24 VA
FL 24/6 2 x 115 Vac 2 x 6 Vac 24 VA
FL 24/8 2 x 115 Vac 2 x 8 Vac 24 VA
FL 24/9 2 x 115 Vac 2 x 9 Vac 24 VA
FL 24/12 2 x 115 Vac 2 x 12 Vac 24 VA
FL 24/15 2 x 115 Vac 2 x 15 Vac 24 VA
FL 24/18 2 x 115 Vac 2 x 18 Vac 24 VA
FL 24/24 2 x 115 Vac 2 x 24 Vac 24 VA
FL 30/5 2 x 115 Vac 2 x 5 Vac 30 VA
FL 30/6 2 x 115 Vac 2 x 6 Vac 30 VA
FL 30/8 2 x 115 Vac 2 x 8 Vac 30 VA
FL 30/9 2 x 115 Vac 2 x 9 Vac 30 VA
FL 30/12 2 x 115 Vac 2 x 12 Vac 30 VA
FL 30/15 2 x 115 Vac 2 x 15 Vac 30 VA
FL 30/18 2 x 115 Vac 2 x 18 Vac 30 VA
FL 30/24 2 x 115 Vac 2 x 24 Vac 30 VA
FL 42/5 2 x 115 Vac 2 x 5 Vac 42 VA
FL 42/6 2 x 115 Vac 2 x 6 Vac 42 VA
FL 42/8 2 x 115 Vac 2 x 8 Vac 42 VA
FL 42/9 2 x 115 Vac 2 x 9 Vac 42 VA
FL 42/12 2 x 115 Vac 2 x 12 Vac 42 VA
FL 42/15 2 x 115 Vac 2 x 15 Vac 42 VA
FL 42/18 2 x 115 Vac 2 x 18 Vac 42 VA
FL 42/24 2 x 115 Vac 2 x 24 Vac 42 VA
FL 52/5 2 x 115 Vac 2 x 5 Vac 52 VA
FL 52/6 2 x 115 Vac 2 x 6 Vac 52 VA
FL 52/8 2 x 115 Vac 2 x 8 Vac 52 VA
FL 52/9 2 x 115 Vac 2 x 9 Vac 52 VA
FL 52/12 2 x 115 Vac 2 x 12 Vac 52 VA
FL 52/15 2 x 115 Vac 2 x 15 Vac 52 VA
FL 52/18 2 x 115 Vac 2 x 18 Vac 52 VA
FL 52/24 2 x 115 Vac 2 x 24 Vac 52 VA