Fluoroplastic power cables for high temperature electricity
Fluoroplastic power cables for high temperature electricity
Product details

Product Details:

Product Name: Fluoroplastic insulated power cable
Product Description:

1: Product Features and Applications

This product is suitable for AC rated voltage0.6/1KV and below are used as fixed transmission and distribution lines, power transmission or motor lead wires, with characteristics such as high temperature resistance, corrosion resistance, acid and alkali resistance, corrosive gas resistance, waterproofing, etc. The electrical performance in high temperature environments is stable, the current carrying capacity is large, and the service life is long. They are widely used in industries such as metallurgy, power, petrochemicals, large construction, and automobile manufacturing.

2: Product execution standards

Q/LB3208.001-2007

Execution of flame retardant and fire resistance characteristics testGB12666-90 standard

3: Usage characteristics

1.Rated AC voltage:U0/U 0.6/1KV

2.Maximum operating temperature: Perfluoroethylene propylene(F46) Insulation not exceeding 200 ℃

Soluble polytetrafluoroethylene (PFA) insulation not exceeding 260 ℃

3.Minimum ambient temperature: Fluoroplastic insulation and sheath

Fixed installation -40 ℃, non fixed installation -15 ℃

4.The temperature for cable installation and laying should not be lower than0 ℃ (fluoroplastic, silicone rubber, and nitrile sheathed cables shall not be lower than -25 ℃).

5.Allowable bending radius of cable: The minimum allowable bending radius for a single core cable is the outer diameter of the cable15 times

The minimum requirement for multi-core cables is 10 times the outer diameter of the cable

4: Basic model and name

outside1

model

product name

Normal operating temperature ℃

FF46

Fluoroplastic insulated and sheathed power cables

-60-200

FF46-22

Fluoroplastic insulated and sheathed steel tape armored power cable

-60-200

FF46P

Fluoroplastic insulated and sheathed copper braided shielded power cable

-60-200

ZR-F46(FV)

Fluoroplastic insulated flame-retardant polyvinyl chloride sheathed power cable

-40-105

ZR-F46-22(FV22)

Fluoroplastic insulated steel tape armored flame-retardant polyvinyl chloride sheathed power cable

-40-105

ZR192-FF46

PFA insulated and sheathed power cables (imported raw materials)

-60-260

ZR192-FF46P

PFA insulated and sheathed copper braided shielded power cable (imported raw materials)

-60-260

ZR192-FF46-22

PFA insulated and sheathed steel tape armored power cable (imported raw materials)

-60-260

YGC-F46(FG)

Fluoroplastic insulated silicone rubber sheathed power cable

-60-180

YGC-F46-22(FG22)

Fluoroplastic insulated steel tape armored silicone rubber sheathed power cable

-60-180

YVF-F46

Fluoroplastic insulated flame-retardant nitrile polyvinyl chloride sheathed power cable

-60-105

YVF-F46-22

Fluoroplastic insulated steel tape armored flame-retardant nitrile polyvinyl chloride sheathed power cable

-60-105

Note: Add soft structure cables to the prototype numberR, Copper wires in conductor cores can be plated with tin.

5: Code name and meaning

outside2

code

Meaning of code

Series code

summary

F(F46)

FEP(F46)

YVF

Nitrile rubber

G

silicon rubber

192

ImportPFA insulation and sheath

ZR(V)

FRPVC(divided into three types: flame retardant at 70 ℃, 90 ℃, and 105 ℃)

22

Steel belt armor

32

Fine steel wire armor

P

Copper braided shielding

R

stranded conductor

6: Main technical indicators

1. The DC resistance of the finished cable conductor (in accordance with GB3956 regulations) shall refer to Table 1 in Appendix A.

At 2.20 ℃, the insulation resistance shall not be less than 500M Ω/KM, and at 180 ℃, the insulation resistance shall not be less than 10M Ω/KM

3. The finished cable shall withstand an AC 50HZ3.5KV/5min voltage test without breakdown.

7: Basic cable specifications and structural parameters

, ,

Wire core*Nominal cross-section(mm2)

Conductor structure

(number of roots/diameter)

mm

Maximum outer diameter of cable(mm)

Calculate weight(kg/km)

FF46

ZR192-FF46

ZR-F46

YGC-F46R

FF46

ZR192-FF46

ZR-F46

YGC-F46

ZR-F46-22

YGC-F46-22

1*1.5

1/1.38

3.2

-

-

25

? ?

1*2.5

1/1.78

3.5

-

-

35

? ?

1*4

1/2.26

3.8

-

-

50

? ?

1*6

1/2.78

4.2

-

-

70

? ?

1*10

7/1.35

5.9

-

-

115

? ?

1*16

7/1.70

6.8

-

-

181

? ?

1*25

7/2.15

8.0

-

-

265

? ?

1*35

7/2.52

9.0

-

-

355

? ?

1*50

10/2.52

10.5

-

-

500

? ?

1*70

14/2.52

12.5

-

-

700

? ?

1*95

19/2.52

14.6

-

-

930

? ?

1*120

24/2.52

16.0

-

-

1190

? ?

1*150

30/2.52

18.0

-

-

1420

? ?

1*185

37/2.52

19.4

-

-

1830

? ?

2*1.5

1/1.38

7.2

8.2

8.5

75

83

215

2*2.5

1/1.78

8.2

10.0

11.5

99

110

280

2*4

1/2.26

9.6

11.4

12.9

135

150

330

2*6

1/2.78

11.0

14.7

15.0

190

200

400

2*10

7/1.35

12.5

15.8

16.8

298

310

550

2*16

7/1.70

16.00

18.0

19.0

423

435

750

2*25

7/2.15

18.50

20.5

23.0

640

645

1050

2*35

7/2.52

22.00

22.5

25.5

843

850

1300

2*50

16*2.00

-

26.0

29.0

1118

1122

1705

2*70

33*1.64

-

28.8

32.0

1537

1540

2250

2*95

33*1.92

-

30.2

34.5

2082

2058

2870

2*120

33*2.15

-

36.2

40.0

2681

2560

3600

2*150

33*2.41

-

39.6

42.9

3180

3150

4315

2*185

33*2.68

-

41.6

45.6

3998

3940

5257

2*240

56*2.34

?

46.0

51.0

5280

5120

6250

3*1.5

1/1.37

8.0

8.2

8.5

100

107

286

3*2.5

1/1.78

9.0

9.8

10.5

140

145

355

3*4

1/2.26

10.0

11.0

12.0

195

201

445

3*6

1/2.78

11.5

13.3

14.3

260

268

490

3*10

7/1.35

14.8

15.8

17.0

422

422

713

3*16

7/1.70

17.5

18.8

20.5

615

640

920

3*25

7/2.15

21.0

22.5

24.00

950

925

1315

3*35

7/2.52

23.0

25.0

26.50

1210

1215

1700

3*50

10/2.52

25.5

27.5

29.0

1656

1655

2340

3*70

14/2.52

27.00

31.0

33.0

2285

2298

3080

3*95

19/2.52

31.00

35.0

37.0

3060

3100

4010

3*120

24/2.52

33.00

38.0

40.2

3859

3830

4953

3*150

30/2.52

35.6

43.00

46.0

4755

4718

6180

3*185

37/2.52

40.0

46.0

49.0

5890

5801

7400

3*240

48/2.52

42.5

53.0

57.5

7450

7377

9000

3*4+1*2.5

1/2.26

11.0

13.0

14.2

230

237

471

3*6+1*4

1/2.78

12.0

14.0

16.0

315

320

600

3*10+1*6

7/1.35

16.0

18.0

19.0

495

501

810

3*16+1*10

7/1.70

18.9

20.5

22.0

745

748

1115

3*25+1*16

7/2.15

21.0

23.0

25.0

1085

1090

1555

3*35+1*16

7/2.52

26.5

29.0

31.5

1450

1410

2255

3*50+1*25

10/2.52

-

32.0

34.2

1940

1900

2780

3*70+1*35

14/2.52

-

35.8

38.0

2720

2690

3700

3*95+1*50

19/2.52

-

43.0

45.5

3585

3580

4800

3*120+1*70

24/2.52

-

45.0

48.0

4650

4580

6010

3*150+1*70

30/2.52

-

47.5

50.5

5480

5400

7010

3*185+1*95

37/2.52

-

52.0

55.0

6890

6810

8600

3*240+1*120

48/2.52

-

58.0

61.0

8750

8610

10525

3*4+2*2.5

1/2.26

11.5

12.0

13.0

280

287

521

3*6+2*4

1/2.78

12.5

14.0

14.8

375

380

660

3*10+2*6

7/1.35

16.0

18.0

19.5

565

571

880

3*16+2*10

7/1.70

22.0

24.0

26.0

860

858

1225

3*25+2*16

7/2.15

24.0

26.0

27.5

1285

1290

1755

3*35+2*16

7/2.52

25.0

27.5

29.0

1650

1610

2455

3*50+2*25

16*2.00

-

34.0

36.5

2240

2200

3080

3*70+2*35

33*1.64

-

37.0

39.2

3120

3090

4100

3*95+2*50

33*1.92

-

40.00

41.8

4285

4280

5500

3*120+2*70

33*2.15

-

45.5

48.5

5550

5480

6910

3*150+2*70

33*2.41

-

52.0

56.2

6380

6300

7910

3*185+2*95

33*2.68

-

56.0

58.0

7890

7810

9600

3*240+2*120

56*2.34

-

60.0

64.5

9950

9810

11725

4*4

1/2.26

10.50

11.5

14.0

238

250

480

4*6

1/2.78

12.30

14.5

15.0

333

340

590

4*10

7/1.35

17.00

20.0

21.3

543

550

868

4*16

7/1.70

19.00

21.5

22.9

806

810

1245

4*25

7/2.15

21.50

25.0

26.5

1184

1190

1680

4*35

7/2.52

-

26.0

27.8

1615

1600

2178

4*50

10/2.52

-

28.2

30.0

2170

2170

2940

4*70

14/2.52

,

-

29.7

30.7

3056

3030

3960

4*95

19/2.52

-

32.5

33.2

4036

4000

5108

4*120

24/2.52

-

36.8

38.8

5120

5080

6400

4*150

30/2.52

-

39.4

41.4

6255

6200

7775

4*185

37/2.52

-

43.7

45.7

7755

7700

9500

Our company's production of five core equal section cables is not listed in this table.

Note: The outer diameter of armored cables refers to the appendixDoutside1Perform calculations.


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!