Guangzhou Dichuan Instrument Co., Ltd
Home>Products>Foshan EMFM series sulfuric acid electromagnetic flowmeter
Foshan EMFM series sulfuric acid electromagnetic flowmeter
The Foshan EMFM series sulfuric acid electromagnetic flowmeter is used for flow control and regulation of water, sewage, mud, pulp, various acids, alk
Product details

EMFMseriesSulfuric acid flowmeterIt can display fluid flow rate and output pulses, simulate current and other signals for flow control and regulation, such as water, sewage, mud, pulp, various acid, alkali, salt solutions, food slurries, etc. Utilizing constant current low-frequency ternary rectangular waves or dual frequency rectangular waves for excitation, which combines the advantages of rectangular wave magnetic fields,Two electrodes are fixed on the measuring tube through the wall in the direction of the pipe diameter. The electrode tip is basically flush with the inner surface of the lining. When the excitation coil is magnetized by bidirectional square wave pulses, a working magnetic field converter with a magnetic flux density of B will be generated in the direction perpendicular to the axis of the measuring tube to amplify and process the flow signalSulfuric acid flowmeterWidely used in industries such as petroleum, chemical, metallurgical, textile, food, pharmaceutical, papermaking, as well as in fields such as environmental protection, municipal management, and water conservancy construction.

Foshan EMFM series sulfuric acid electromagnetic flowmeter

Product features:
Series nominal diameter DN10~DN5000. There are multiple options for sensor lining and electrode materials;
Measurement is not affected by changes in fluid density, viscosity, temperature, pressure, and conductivity;
The converter adopts a novel excitation method, with low power consumption, stable zero point, and high accuracy. The flow range can reach 1502:1;
There are no obstructing flow components or pressure loss inside the measuring tube, and the requirements for straight pipe sections are relatively low;
The converter can be integrated or separated from the sensor;
The converter adopts a 16 bit high-performance microprocessor, 2x16 LCD display, convenient parameter setting, and reliable programming;
The flowmeter is a bidirectional measurement system, equipped with three integrators and multiple outputs: current, pulse, digital communication, etc HART;

Main technical data:
Technical data of the whole machine and sensors

Execution standards

JB/T 9248—1999

Nominal Diameter

15、 20. 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000, 2200, 2400, 2600, 2800, 3000

Zui high flow rate

15m/s

accuracy

DNl5~DN600

Indication: ± 0.2999% (flow rate ≥ 0.01m/s); ± 3mm/s (flow rate<0.01m/s)

DN700—DN3000

± 0.04999% of the indicated value (flow rate ≥ 0.08m/S); ± 4mm/s (flow rate<0.0799m/s)

Fluid conductivity

≥5uS/cm

nominal pressure

4.0MPa

1.6MPa

1.0MPa

0.6MPa

6.3、 10MPa

DNl5~DN150

DNl5~DN600

DN200~DN1000

DN700~DN3000

Special Orders

ambient temperature

sensor

—25℃—60 ℃

Converter and integrated model

—10℃—60 ℃

Lining material

Polytetrafluoroethylene, chloroprene rubber, polyurethane, perfluoroalkoxy (F46), mesh PFA

Zui high fluid temperature

body type

70℃

separated

Polychloroprene rubber lining

80℃120 ℃ (specify when ordering)

Polyurethane lining

80℃

PTFE lining

100℃150 ℃ (specify when ordering)

Perfluoroethylene propylene (F46)

Mesh PFA

Signal electrode and ground electrode materials

Stainless steel 0Crl8Nil2M02Ti, Hastelloy C, Hastelloy B, titanium, tantalum, platinum/iridium alloy, stainless steel coated with tungsten carbide

Electrode gua knife mechanism

DN300—DN3000

Connecting flange material

carbon steel

Grounding flange material

Stainless steel 1Cr18Ni9Ti

Imported protective flange materials

DN65—DNl50

Stainless steel 1Cr18Ni9Ti

DN200~DNl600

Carbon steel and stainless steel 1Cr18Ni9Ti

Shell protection

DNl5DN3000 separable rubber or polyurethane lined sensor

IP65Or IP68

Other sensors, body type flow meters, and separate converters

IP65

Distance (separated type)

The distance between the converter and the sensor is generally not more than 100m

Foshan EMFM series sulfuric acid electromagnetic flowmeter
Converter technology data

power supply

exchange

85—265V, 45—400Hz

direct-current

11—40V

Operation keys and display

Touch-tone

4A thin film button can be used to set and select all parameters, and the converter can also be programmed using a PC (RS232);

3LCD with wide viewing angle, wide temperature range, and backlit display;

The first line displays the traffic value;

The second line displays the flow unit;

The third line displays the percentage of traffic, total forward, total reverse, total difference, alarm, and flow rate.

Magnetic key type

2A magnetic key is used to display parameter selection and reset, and a PC (RS232) is used to program the converter settings;

2LCD with wide viewing angle, wide temperature range, and backlit display:

Line 1: Magnetic key selection: Display flow percentage, forward total amount, reverse total amount, difference total amount, alarm, flow rate.

Line 2: Display traffic.

Internal integrator

Positive total, negative total, and differential total.

output signal

Unidirectional analog output

Fully isolated, load ≤ 600D. (at 20mA);

Upper limit: 0-21mA optional, 1mA per level;

Lower limit: 0-21mA optional, 1mA per level;

Programming for forward and reverse flow output modes.

Bidirectional analog output

The lower limit is. Or 4mA, other same unidirectional analog outputs.

Bidirectional pulse output

Two outputs correspond to forward and reverse flow rates, with a frequency range of 0-800Hz and an upper limit of 1-800Hz to choose from. Each IHz level is available;

Square wave or selected pulse width, with an upper limit of 2.5S and 1ms per level;

Passive isolation transistor switch output, capable of absorbing 250mA current and withstanding 35V voltage.

Dual channel alarm output

Programmable alarm for high/low flow rate, air traffic control, fault status, positive/negative flow rate, analog over range, pulse over range, pulse small signal cutoff, with optional output polarity;

Transistor switch output with isolation protection, capable of absorbing 250mA current and withstanding 35V voltage (not isolated from pulse output)

digital communication

 

RS232, RS485,HART

Selection of lining

Lining material

Performance

Zui high medium temperature

scope of application

body type

separated

 

Polytetrafluoroethylene (F4)

It is a plastic with the most stable chemical properties, capable of withstanding boiling hydrochloric acid, sulfuric acid, nitric acid, and aqua regia, as well as concentrated alkali and various organic solvents. Not resistant to corrosion from chlorine fluoride, high-temperature chlorine fluoride, high flow rate liquid fluorine, liquid oxygen, and self oxygen.

70℃

100℃150℃ (Special order required)

1Strong corrosive media such as concentrated acid and alkali. 2. Sanitary media.

Perfluoroethylene propylene (F46)

Same as F4, its wear resistance and negative pressure resistance are higher than F4.

ditto

 

Polyfluoroethylene (Fs)

The upper limit of applicable temperature is lower than that of polytetrafluoroethylene, but the cost is also lower.

80℃

 

neoprene

1Has excellent elasticity, high tensile strength, and good wear resistance. 2. Resistant to corrosion in general low concentration acid, alkali, and salt media, but not resistant to corrosion in oxidizing media.

80℃120℃ (Special order required)

Water, sewage, and weakly abrasive slurry.

polyurethane

1Extremely strong wear resistance.

2Poor corrosion resistance.

80℃

Neutral strong abrasion slurry, coal slurry, mud


Selection of imported protective flanges and grounding flanges (or grounding rings)

Orchid species

Scope of application

Grounding flange (or grounding ring)

Suitable for non-conductive pipelines such as plastic pipes, but sensors with grounding electrodes do not require them.

Import protection flange

Choose when the medium has strong wear resistance.

Selection of electrodes

Electrode material

Corrosion resistance and wear resistance

Stainless steel 0Crl8Nil2M02Ti

Used for weakly corrosive media such as industrial water, domestic water, sewage, etc., suitable for industrial sectors such as petroleum, chemical, steel, as well as municipal and environmental protection fields.

Hastelloy B

It has good corrosion resistance to all concentrations of hydrochloric acid below boiling point, as well as to non chlorinated acids, bases, and non oxidizing salt solutions such as sulfuric acid, phosphoric acid, fluoric acid, and organic acids.

Hastelloy C

Can withstand corrosion from non oxidizing acids such as nitric acid, mixed acids, or mixed media of chromic acid and sulfuric acid, as well as corrosion from oxidizing salts such as Fe, Cu, or other oxidants such as hypochlorite solutions above room temperature and seawater

titanium

Capable of withstanding corrosion from seawater, various chlorides and hypochlorites, oxidizing acids (including fuming sulfuric acid), organic acids, and alkalis. Not resistant to the corrosion of relatively pure reducing acids (such as sulfuric acid, hydrochloric acid), but if the acid contains oxidants (such as nitric acid, Fc++, Cu++), the corrosion is greatly reduced.

tantalum

It has excellent corrosion resistance and is very similar to glass. Except for fluoric acid, fuming sulfuric acid, and alkali, it can almost withstand corrosion from cutting chemical media (including boiling point hydrochloric acid, nitric acid, and sulfuric acid below 50 ℃). Dig in alkali; Corrosion resistance.

Platinum/titanium alloy

Almost capable of cutting chemical media, but not suitable for aqua regia and ammonium salts.

Stainless steel coated with tungsten carbide

Used for non corrosive and highly abrasive media.

Note: Due to the wide variety of media and the complex factors such as temperature, concentration, and flow rate that affect their corrosiveness, this table is for reference only. Users should make their own choices based on the actual situation, and if necessary, conduct corrosion resistance tests on the selected materials, such as hanging plate tests.


EMFMseriesSulfuric acid flowmeterinstrument selection
Range confirmation
General industrial use
Sulfuric acid flowmeterThe flow velocity of the measured medium should be between 2-4m/s. In special circumstances, the low flow velocity should not be less than 0.2m/s, and the maximum flow velocity should not exceed 8m/s. If the medium contains solid particles, the commonly used flow rate should be less than 3m/s to prevent excessive friction between the lining and the electrode; For viscous fluids, the flow velocity can be chosen to be greater than 2m/s. A higher flow velocity helps to automatically eliminate the effect of viscous substances attached to the electrode, which is beneficial for improving measurement accuracy.
Under the condition that the range Q has been determined, the size of the flowmeter diameter D can be determined based on the range of flow velocity V mentioned above, and its value can be calculated by the following formula:
Q=πD2V/4
Q: Flow rate (㎡/h) D: Inner diameter of pipeline V: Flow rate (m/h)

Sulfuric acid flowmeterThe range Q of the flow meter should be greater than the expected large flow rate value, while the normal flow rate value should be slightly greater than 50 of the full scale of the flow meter.
EMFM series
Sulfuric acid flowmeterReference flow range

Caliber mm

Flow range m3/h

Caliber mm

Flow range m3/h

φ15

0.060~6.360

φ450

57.230~5722.650

φ20

0.110~11.30

φ500

70.650~7065.00

φ25

0.180~17.660

φ600

101.740~10173.60

φ40

0.450~45.220

φ700

138.470~13847.40

φ50

0.710~70.650

φ800

180.860~18086.40

φ65

1.190~119.40

φ900

228.910~22890.60

φ80

1.810~180.860

φ1000

406.9400~40694.40

φ100

2.830~282.600

φ1200

553.900~55389.60

φ150

6.360~635.850

φ1600

723.460~72345.60

φ200

11.300~1130.40

φ1800

915.620~91562.40

φ250

17.660~176.25.0

φ2000

1130.40~113040.00

φ300

25.430~2543.400

φ2200

1367.780~136778.40

φ350

34.620~3461.850

φ2400

1627.780~162777.60

φ400

45.220~4521.60

φ2600

1910.380~191037.60

EMFMseriesSulfuric acid flowmeterSelection spectrum

model

caliber

EMFM

10~2600

code

Installation form

Y

Integrated

F

split type

code

Converter model

ZA

rotundity

ZB

square

code

output signal

I.4

4~20mA

f

Frequency 1KHz

Rs

Serial communication (485)

C

control output

code

Explosion proof requirements

N

No explosion-proof

EX

Explosion proof (only applicable to split type)

code

medium temperature

T1

≤65℃

T2

≤120℃

T3

≤180℃(Only applicable to split type)

code

Lining material

NE

Chloroprene rubber (≤ 65 ℃)

PTFE

Polytetrafluoroethylene (≤ 189 ℃)

PVC

Polyvinyl chloride (≤ 70 ℃)

code

Electrode material

316L

stainless steel

HC

Hastelloy C

HB

Hastelloy B

Ti

titanium

Ta

tantalum

Guangzhou, ShenzhenZhuhai, Shantou, Foshan, Shaoguan, Zhanjiang, Zhaoqing, Jiangmen, Maoming, Huizhou, Meizhou, Shanwei, Heyuan, Yangjiang, Qingyuan, Dongguan, Zhongshan, Chaozhou, Jieyang, Yunfu

Guangzhou City: Yuexiu District Liwan District Haizhu District Tianhe District Baiyun District Huangpu district PANYU Huadu Luogang District, Nansha District Zengcheng City Conghua

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!