The HX-DT series toxic gas detector detects gas concentration online, displays concentration values (display type), alarms for exceeding standards (alarm type), and transmits gas concentration to the collection equipment through communication cables. Adopting modular design (including detector module and sensor module), anti misplacement lockable connection wires are used between modules. An independent sensor module that can be paired with multiple types of sensors. Implemented on-site maintenance free, allowing for direct module replacement without the need for re zeroing, calibration, or setup. The detector equipped with an infrared remote control can achieve remote operation up to 5 meters away.
Principle: The detector adopts an imported gas sensor, which can convert the gas concentration signal into a voltage signal in a linear proportion. After amplification and processing, it is sent to the microcontroller for analog-to-digital conversion, and the converted data signal is analyzed and processed linearly by software. Handling process: Fault diagnosis concentration judgment concentration processing conversion output. The output signal is transmitted to the controller (HXK series) through RS485 standard signal/4-20mA standard signal.
This series of detectors has high stability, low power consumption, multiple output modes, and strong anti-interference ability. Especially suitable for flammable and explosive places with harsh working environments that are difficult for workers to approach. This product can be widely used in departments such as petrochemicals, oil fields, oil depots, liquefied gas stations, coal mines, environmental protection, fire protection, etc. It is an ideal monitoring instrument to ensure property and personal safety.
execution standard
◆GB12358-2006 General Technical Requirements for Workplace Gas Detection and Alarm Devices
◆GB3836.1-2010 Explosive Atmosphere Part 1: General Requirements for Equipment
◆GB3836.2-2010 Explosive Atmosphere Part 2: Equipment Protected by Explosion proof Enclosures "d"
Product actual photos




Technical Specifications
| Gas detection | toxic gas | ||
| sampling method | Diffusion type | ||
| Detection Principle | Electrochemical/Photoionization (PID) | ||
| Range | 0-10, 0-50, 0-100ppm ········ (adjusted according to gas type) |
||
| Testing Unit | PPM | ||
| Alarm concentration | Set alarm points based on the type of gas being detected |
||
| Working Voltage | DC24V±6V | ||
| power waste | 3.5W | ||
| Signal transmission distance | ≤ 1500 meters | ||
| output signal | Three wire system (4-20mA standard signal)/Four wire system (RS485 standard signal) | ||
| electrical interface | G1/2 "internal thread | ||
| Explosion-proof rating | Exd II CT6 Gb | ||
| Protection level | IP66 | ||
| texture of material | aluminum alloy | ||
| relative humidity | ≤93%RH | ||
| pressure range | 86kPa~106kPa | ||
| Display | optional | ||
| Calibration | HX series controller/probe motherboard button/remote control (with display) |
||
Indicators for implementing national/industry standards
| Detection Principle | Electrochemical formula |
Gas detection | Toxic and harmful gases such as CO and NH3 | ||
| Catalytic combustion/semiconductor/infrared | Flammable gases such as alkanes |
||||
| Alarm error | ± 15% of the alarm set value (electrochemical) | Indication error (displayed on the controller) |
± 5% F.S (electrochemical) ± 5% F.S (flammable) | ||
| ± 3% LEL (flammable) | |||||
| Response time (T90) | ≤ 60s (electrochemical reference schedule) | Operating temperature | -20 ℃~+50 ℃ (electrochemical) | ||
| ≤ 30s (flammable) | -40 ℃~+70 ℃ (flammable) | ||||
| Sensor storage life | 1 year (catalytic/semiconductor) | Sensor lifespan | 3 years (catalysis)/5 years (semiconductor)/10 years (infrared) | ||
| 6 months (electrochemistry) | 1-2 years (electrochemistry) | ||||
| storage environment | Catalysis/semiconductor (storage temperature -20 ℃ -+50 ℃, storage humidity ≤ 95% RH); Electrochemistry (0 ℃ -20 ℃, storage humidity 15% -60% RH); There are no organic solvents, flammable liquids, flammable gases or sulfides, chlorides, lead, silicon elements, or interfering toxic and harmful gases on site. |
||||
| Gas to be tested | range | Alarm Settings | Factory default alarm settings | ||
| CO | 0-1000ppm (adjustable) | lower limit | 200ppm (adjustable) | ||
| 高限 | 500ppm (adjustable) | ||||
| H2S | 0-100ppm (adjustable) | lower limit | 20ppm (adjustable) | ||
| 高限 | 50ppm (adjustable) | ||||
| NH3 | 0-100ppm (adjustable) | lower limit | 20ppm (adjustable) | ||
| 高限 | 50ppm (adjustable) | ||||
| CL2 | 0-10ppm (adjustable) | lower limit | 2ppm (adjustable) | ||
| 高限 | 5ppm (adjustable) | ||||
| O2 | 0—30%VOL | lower limit | 18% VOL (modifiable) | ||
| 高限 | 23% VOL (modifiable) | ||||
| VOC | 0-100ppm/0-1000ppm | lower limit | 20/200ppm (adjustable) | ||
| 高限 | 50/500ppm (adjustable) | ||||
| flammable gas | 0-100%LEL/ppm | lower limit | 20%LEL | ||
| 高限 | 50%LEL | ||||
◆ Linear algorithm adapted to various sensors, capable of detecting multiple gases
◆ Adopting imported sensors, corresponding rapid and accurate
◆ Anti interference, anti poisoning, long lifespan
◆ On site maintenance without calibration and setting is convenient and fast
◆ Coexistence of multiple communication methods including three wire and four wire
◆ Infrared remote control operation zero calibration