Brief introduction
The CYB623 series industrial digital differential pressure transmitter uses high-precision and high stability dual isolation diaphragm differential pressure sensors. Through strict and precise temperature compensation, signal amplification, V/I conversion, the pressure difference, flow rate and other parameters are reliably converted into industrial standard signal outputs. This product adopts an industrial explosion-proof shell and a three-and-a-half-inch LED on-site display, suitable for differential pressure control in general industrial sites.
This product has been screened through long-term aging and stability assessment processes, and has functions such as resistance to overvoltage, overcurrent, reverse, lightning strikes, and electromagnetic interference, with high cost-effectiveness. The product has stable and reliable performance, easy installation, and is widely used in fields such as petroleum, chemical, metallurgy, power, hydrogeology, etc. It realizes automatic measurement and control of differential pressure, liquid level, and flow rate in industrial processes.
2、 Technical performance
Range of measurement |
0~10, 35…1000(KPa) |
0~1…2、3.5(MPa) | |
quietpress |
range2timesperhapsTake the minimum value of 7MPa |
Measurement medium |
Gas and liquid compatible with 316L stainless steel |
Output signal |
4~20mA two-wire system |
rs485 communication | |
Display mode |
31/2Position LED |
Supply voltage |
+12~+36VDC (calibrated value is+24VDC) |
accuracy |
±0.2%F.S ±0.3%F.S |
Long term stability |
≤± 0.2% F.S/year |
Medium temperature |
-20~+85℃ |
Response time |
≤1ms |
Pressure interface |
M20 × 1.5 or user-defined |
Explosion proofLogo |
ExiaIICT6 |
Protection level |
IP65 |
3、 Product Features
● Double sided 316L stainless steel isolation membrane structure
31/2LED display
High precision and good long-term stability
● Anti electromagnetic interference design
● Zero point and full-scale output adjustable
● Intrinsic safety explosion-proof
4、 Exterior structure

5、 Installation and use
The installation and connection of the differential pressure transmitter are shown in the figure. The transmitter is fixedly installed, and the high and low medium pressures are introduced into the "H" high pressure chamber and "L" low pressure chamber of the transmitter through the pressure pipe and balance valve. Pay attention to the static pressure parameters and strictly prohibit one-way overload pressurization and pressure resistance to avoid damage.
6、 Product selection
CYB623 |
Industrial digital differential pressure transmitter |
||||||
0~X (KPa or MPa) |
range |
||||||
J02 |
±0.2%FS |
||||||
J03 |
±0.3%FS |
||||||
C1 |
4~20mA output |
||||||
C4 |
rs485 communication |
||||||
C0 |
special |
||||||
M1 |
M20 × 1.5 external thread |
||||||
M0 |
special |
||||||
F5 |
Wiring terminal outgoing line |
||||||
F0 |
special |
||||||