The JL9648 displacement display instrument is a high-precision displacement display instrument independently developed by Jinan Jingliang Electronic T
Product details


JL9648The displacement display instrument is a high-precision displacement display instrument independently developed by Jinan Jingliang Electronic Technology Co., Ltd. The instrument can input pulse signals orRS485Communication, can be input according to user requirements220vVoltage or24vVoltage,JL9648The displacement display instrument adopts internationally recognized terminals, with convenient external dimensions and installation. It also has parameter password protection function, dual relay bidirectional action, bidirectional automatic reset and other functions.

1、 Parameter description of displacement display instrument:

code Instructions set the scope default value

Pn-00 The position of the decimal point (the number of decimal places in the displayed value). 0~5 2

Pn-01 counting method0single laneB 1-single laneA2-Dual channel quadruple frequency 0~2 Invalid simulation

Pn-02 Counting magnification, after linear calibration, the proportional relationship can be set 0.000~9999.999 1.00000

Pn-03 The lower limit value and decimal point are defined by the setting. 0~999999 3.0000

Pn-04 The upper limit value and decimal point are defined by the settings. 0~9999999 5.0000

Pn-05 485Serial port baud rate setting 09600 bps, 119200

2:38400, and so on 0~5 0

Pn-06 Initial value, 0~9999999 0

Pn-07 Parameter protection password, set parameters to be password protected when non-zero.9999Universal Password 0000~9999 0000

Pn-08 The unit of relay reset time is seconds,0.0Not resetting. note1. 0.0-999999.9 0.0

Pn-09 Input filter coefficients,0To avoid filtering,9The strongest level. 0~5 none

Pn-10 485Please refer to the communication protocol for the mailing address. 00-99 01

Pn-11 Pn11=0≤ lower limit action and ≥ upper limit action, no action in between Pn11=1≥ lower limit action, and ≥ upper limit action.Pn08=0The action of the relay is determined based on the set value

Pn08For non0time According to the set reset timetAutomatic reset,

Pn11=3The relay operates in both directions, pressPn08Set bidirectional automatic reset time 0~2 0

Pn-12 Adjustment of relay action accuracy 0-99 2

Pn-13 Serial port output content 0 - Display value 1-source code 0-1 0

Pn-18 Display content0 1displacement

2speed1relay

3Number of actions (relay actions based on displacement)2relay

4Number of actions (relay actions based on displacement)1relay

5Number of actions (relay operates based on speed)2relay Number of actions (relay operates based on speed) 0

0-5 PN-19

JL9648位移数显示仪说明书

Speed modeUpdate intervalII

JL9648 Definition of wiring for displacement display instrument: signal name external supply external supply

External reset sensor External terminal +12v +5v GND reset B A

B- 9 10 11 12 13 14 15 16

A- 1 2 3 4 5 6 7 8

Upper terminal Bottom terminal External terminal220VAC J2Lower the relay J1 Upper relay

RXDTXD JL9648 Power supply for displacement display instrument Normally Open ContactNormally Open Contact

定制r232

1JL9648

1Parameter settings for displacement display instrument: When there is no password protectionPress the function key during normal operation(MO)More than seconds, the main display window showsPn-00

2To enter the parameter settings, you can use the ↑↓ keys to loop through the display until you want to modify the parameter Pn-XXWhen the main window displays parameters“Pn-XXAfterwards, press the OK button(

3En )Entering the parameter setting state, the last digit of the parameter displayed in the main window is flashing;To modify the value, make sure the current modification bit is the flashing bit. If not, you can press the function key(MO)Cycle from right to left to change the position of the flashing bit, with different parameters displaying different numbers of bits. Use the ↑↓ keys to change the value, set the parameters, and then press the OK button(En)Jump out of parameters

4Pn0XX The setting,Press(

5MO )Return to work mode.When entering any state in the settings, if you press the reset button(

2CL.

)The exit will not be saved, but the newly modified parameters will be temporarily valid until the power is turned off (except for the serial port baud rate), and will be restored to their previous settings when powered on again. This function can be used to view parameters.When there is password protectionWhen the function key is pressed and the above method is used to enter the corresponding settings, the main window will display“0000Pn-CO.”Enter password input mode. At this moment, the window displaysFlashing at the lowest position, follow the above steps and use the ↑↓ keys and function keys(MO)Enter the correct password and press the OK button(En)Confirm that the program has entered the parameter setting state. If the password is entered incorrectly or the reset button is pressed(

CL.)Then the program returns to its working state.III

1. JL9648Calibration function of displacement display instrumentPress the function key in normal mode(MO+1EN)Simultaneously hold downMore than seconds, the window displays 0000C-00004(At this time, it is in the password input state, not necessarily1111, could be anyNumber of digits, default password, cannot be changed, use the ↑↓ keys to modify values and function keys(1111MO)Move the flashing bit and enter the correct passwordPress the OK button(En)Enter calibration, the window displays“0Cn--0”Display“”And flash (if not flashing, pressENBelow), this number is the calibration point, which can be adjusted using the ↑↓ keys within the range of2-9Press the OK button(1En )Enter calibration (if adjusting the number of calibration points to, then no calibration will be performed)Window display“Cn--1”Press again6EN0Once, the window displaysA“”And the lowest position flashes, at this time the device is adjusted to the starting position, enter the display value of the first point, and pressEnAfter confirmation, the window will display“Cn-2”Press againENAfter confirmation, enter the second point display value as described above (indicating that the device needs to be adjusted to the second point position at this time), and then press the OK button( En)Enter the next calibration pointWindow display“Cn--3”Press again(EnRepeat the process until the set calibration point is reached, then press the OK button(En

2. )Save calibration parameters and exit to return to normal state. If the calibration is not completed, press the reset button(

CL.

)Cancel the previous calibration value, please proceed with caution!When there is password protection, the parameter settings are the same as those mentioned abovePeak functionIn working mode, press the OK button first(En)Press the ↑ key again, thenMAX-PThe indicator light is on,PVThe window always displays the peak displacement value. Press the OK button again(En

)Press the ↑ key again,

MAX-P5The indicator light goes out and exits the peak displacement state.