Instrument Introduction LC-500 Analytical Chromatography Instrument - High Precision, Rapid Preparation, High Efficiency
Product details
Instrument Introduction                               
LC-500 Analytical Typechromatograph--High precision, rapid preparation, and high efficiency.
The experience and technology gained from the widespread use of LC-500 in various fields such as laboratory, semi preparative chromatography, chromatography, and counter current chromatography have been applied to the development of new technologies, continuously enriching the various functions required for laboratory analysis and production purification preparation.
detailed introduction


Isometric HPLC system: It is composed of the minimum number of component units, including solvent infusion pump, UV detector, 7725i injection valve, liquid chromatography column, workstation, and injection needle. The system configuration is the simplest and can meet the majority of routine analysis needs.

to configure:

Isometric system

specific configuration

quantity

Order Number

LC-500A High Pressure Infusion Pump

1

WK500-0102-002

SPD-500 UV detector

1

WK500-0101-001

7725i injection valve

1

WK500-0413-001

Chromatography workstation

1

WK500-0301-001

250*4.6 5um C18 柱

1

WK500-0401-024

50ul flat head injection needle

1

WK500-0409-002


·LC-500 EfficientLiquid ChromatographBy using a static motor control circuit, the automatic feedback tracking function of the motor control signal is achieved, effectively improving the accuracy of motor control and ensuring the reliability and stability of the pump
·Floating self correcting sealing ring technology and pump head self-cleaning can extend the service life of the sealing ring, ensuring the durability and high efficiency of the instrument
·Convenient and easy-to-use flow and pressure calibration functions ensure high precision and stability of the instrument
·Using two gradient running program designs: linear gradient and step gradient are optional;
·Programmable solvents and compression factors that can automatically compensate
·Complete pre cleaning function for quick solvent replacement
·Adopting holographic dual grating technology
·Applying high-precision photodiode design to expand linear range
·Convenient, fast and unique self correction function for light intensity gain coefficient
·Unique holmium glass cell design, full wavelength scanning, convenient and accurate wavelength correction
·Universal sample cell design, easy to replace between trace and constant cells

·Deuterium lamp replacement is simple, fast, and can be used without calibration

LC-500High performance liquid chromatographyTechnical Specifications

infusion pump
flow range 0.001-10ml/min
accuracy ±1%
precision 0.25%
pressure range 0-42MPa
gradient 2 yuan
Gradient method The gradient elution internal software can be self controlled and controlled through a PC and pump
power supply 100 to 240 VAC, 50 to 60Hz, 80watts
weight 8.0kg
detector
Light source Deuterium lamp/tungsten lamp
Optical path design Monochromator with dual channel silicon photodiode detector
wavelength range 190-700nm increments by 1nm, can be set by keyboard or RS232/485/USB
bandwidth <6m
wavelength accuracy ±1nm
wavelength repeatability 0.2nm
Absorption range 0.0005AU/mV-4AU/mV
Data system output 4AU/V injection signal control, automatic zeroing, supports dual output of integrator and recorder
noise ±0.5x10-5AU
drift 2x10-4AU(P-P)
sample pool Standard conical pool (10mm optical path, 4.5ul volume), semi prepared (5mm optical path, 3.5ul volume)
power supply 100 to 240 VAC, 50 to 60Hz, 80watts