◆ Product Introduction
DHPS electric high-pressure single seat regulating valve is a type of regulating valve with an upward guiding structure. The valve has a compact structure, low pressure drop loss, large flow rate, wide adjustable range, large guiding area of the valve core guiding part, and good anti vibration performance. The leakage rate of the regulating valve complies with ANSI Bl6.104 standard. The product complies with GB/T4213-92 JB/T7387-94 。
◆ Technical parameters
Type: Single seat cast ball valve
Nominal diameter: 25, 40, 50, 80mm
Nominal pressure: ANSI 900, 1500, 2500 JIS 63K
Connection type: flange connection: RF、RJ
Flange standards: JIS B2201-1984, ANSI Bl6.5-1981, JB79-59, etc
Welding connection: socket welding SW (25-80mm), butt welding BW (80mm)
Valve structure
Materials: Carbon steel (ZG230-450), CrMo steel, stainless steel (ZGlCrl8Ni9Ti, ZGlCrl8Nil2Mo2Ti
ZGOOCr18Ni12Mo2Ti, etc
Upper valve cover: room temperature type (P):- 5~+230 ℃, elongation type I (EI):+230~+566 ℃
Note: The working temperature should not exceed the allowable range of various materials.
Cover type: bolt compression type
Filler: impregnated polytetrafluoroethylene asbestos filler, asbestos woven filler, graphite filler
Valve core type: single seat plunger valve core
Flow characteristics: Equal percentage characteristics (% C) and linear characteristics (LC), refer to Figure 1
Materials: Stainless steel (1Cr18Ni9Ti, 1Cr18Ni12Mo2Ti, 17-4PH, 9Cr18, 316L), stainless steel overlay with Stellite alloy, titanium, and corrosion-resistant alloys, etc
◆ Executing Agency
Type DKZ series electric actuator; 361L series electronic electric actuator; SKZ series electronic electric actuator; PSL series electronic electric actuator input signal DKZ actuator: Type II 0-10mA · DC (input resistance 200 Ω); Type III 4-20mA · DC (input resistance 250 Ω)
361L actuator: 4-20mA · DC or 1-5V (input resistance 250 Ω), SKZ actuator: 4-20mA · DC, 1-5V DC
PSL actuator: 4-20mA · DC
Power supply voltage DKZ actuator: 220V, 50Hz, 361L actuator: 220V, 50/60Hz
SKZ actuator: single-phase control 220V · AC ± 5%;
PSL actuator: single-phase control 220V, 50Hz; Three phase control 380V, 50Hz
Manual mechanism DKZ actuator: Handwheel; 361L actuator: clutch type; SKZ actuator: handwheel; PSL actuator: Handwheel
Valve action type: electrically closed or electrically open
Performance
Leakage rate metal valve seat: less than 0.01% of the rated capacity of the valve, in compliance with ANSI B16.104-1976 Class IV
The differential configuration DKZ actuator is 1.5%; 2% for 361L actuator; 1% for SKZ actuators; Equipped with PSL actuator&nb, Sp; is 1%
The basic error of the DKZ actuator is ± 2.5%; Equipped with 361L actuator for ± 2%; The SKZ actuator is equipped with a tolerance of ± 1.5%; Equipped with PSL actuator for ± 1%
Adjustable range 50:1 Cv value and travel
◆ Structural images