A brief introduction to low-temperature water bath shaker with refrigeration: Our factory produces a digital water bath oscillator (shaker), also known as a water bath constant temperature shaker. There are three types of oscillation modes according to their functions: reciprocating water bath oscillator (shaker), rotary water bath oscillator (shaker), and dual function water bath oscillator (shaker). There are two main series of oscillation modes according to their functions: room temperature water bath oscillator (shaker) and low-temperature water bath oscillator (shaker) The water bath oscillator (shaker) has a stainless steel universal fixture, digital temperature control, stepless speed regulation, and good thermal cycling function It is a versatile biochemical instrument that is indispensable laboratory equipment for precision cultivation and preparation in fields such as plants, biology, microbiology, genetics, viruses, environmental protection, and medicine.
The application range of low-temperature water bath shaker with refrigeration: The low-temperature water bath shaker with refrigeration, also known as the fully warm water bath shaker, is mainly suitable for the oscillation cultivation of various liquid and solid compounds such as biology, biochemistry, cells, and bacterial strains in various universities, oil and chemical engineering, health and epidemic prevention, environmental monitoring and other scientific research departments. The low-temperature water bath oscillator (shaker) with refrigeration has the characteristics of reasonable structure, easy operation, and high stability, making it an ideal equipment for laboratory workers to handle with ease.
2、 Main technical performance of low-temperature water bath shaker:
1、 Power supply: 220V 50Hz
2、 Overall power: 1800w
3、 Timing range: 0-120 minutes
4、 Oscillation frequency: starting -300 revolutions per minute, adjustable
5、 Oscillation amplitude: 20mm
6、 Constant temperature range: 5 ° C-100 ° C (with refrigeration)
7: Workload: 20kg
8: Dimensions: 685 × 460 × 900mm
IIILow temperature water bath shakerinstructions
1、Please read this manual carefully before use.
2、The working surface of the machine should not be excessively smooth (such as tiles, etc.).
3、The electrical rated parameters of the socket provided by the user should not be less than the electrical rated parameters of the machine, and there should be good grounding measures.
4、The whole machine is strictly prohibited from being used in an environment with direct sunlight.
5、The speed control should start slowly from low speed to high speed.
6、The machine may experience some displacement during high-speed oscillation, so it should be monitored by someone during use.
4Low temperature water bath shakerinstructions
2、The working surface of the machine should not be excessively smooth (such as tiles, etc.).
3、The electrical rated parameters of the socket provided by the user should not be less than the electrical rated parameters of the machine, and there should be good grounding measures.
4、The whole machine is strictly prohibited from being used in an environment with direct sunlight.
5、The speed control should start slowly from low speed to high speed.
6、The machine may experience some displacement during high-speed oscillation, so it should be monitored by someone during use.
4Low temperature water bath shakerinstructions
1、Load the test bottle and maintain balance. If it is a dual function model, set the oscillation mode. (For detailed settings, please refer to the diagram below *)
2、Turn on the power and set the timer according to the surface scale of the machine. If you need to work for a long time, adjust the timer to“normally open'Location.
3、Turn on the power switch and set the constant temperature:
(1)Place the control switch in“setting'At this point, the temperature displayed on the screen is the set temperature. Adjust the knob to set it to the temperature you need for your work. (The working temperature you set should be higher than the ambient temperature. At this time, the machine starts heating up and the yellow indicator light is on. Otherwise, the machine will not work.)
(2)Place the small switch in the control section“measure'At this time, the temperature displayed on the screen is the actual temperature of the air inside the test chamber. As the temperature inside the chamber changes, the displayed number will also change accordingly.
(3)When heated to the desired temperature, the heating will automatically stop and the green indicator light will turn on; When the heat inside the test chamber dissipates below the temperature you set, a new round of heating will begin.
4Activate the oscillation device:
(1)Turn on the oscillation switch on the control panel, and the indicator light will turn on.
(2)Adjust the oscillation speed knob to the desired oscillation frequency.
5After completing the work, cut off the power and set the speed control knob and temperature control knob to the lowest point.
6Clean the machine and keep it clean.
2、Turn on the power and set the timer according to the surface scale of the machine. If you need to work for a long time, adjust the timer to“normally open'Location.
3、Turn on the power switch and set the constant temperature:
(1)Place the control switch in“setting'At this point, the temperature displayed on the screen is the set temperature. Adjust the knob to set it to the temperature you need for your work. (The working temperature you set should be higher than the ambient temperature. At this time, the machine starts heating up and the yellow indicator light is on. Otherwise, the machine will not work.)
(2)Place the small switch in the control section“measure'At this time, the temperature displayed on the screen is the actual temperature of the air inside the test chamber. As the temperature inside the chamber changes, the displayed number will also change accordingly.
(3)When heated to the desired temperature, the heating will automatically stop and the green indicator light will turn on; When the heat inside the test chamber dissipates below the temperature you set, a new round of heating will begin.
4Activate the oscillation device:
(1)Turn on the oscillation switch on the control panel, and the indicator light will turn on.
(2)Adjust the oscillation speed knob to the desired oscillation frequency.
5After completing the work, cut off the power and set the speed control knob and temperature control knob to the lowest point.
6Clean the machine and keep it clean.
5Low temperature water bath shakermatters needing attention:
1Equipment should be placed on a sturdy workbench, with a clean and tidy environment and good ventilation.
2The power sockets provided by users should have good grounding measures.
3It is strictly prohibited to move the machine during normal operation.
4It is strictly prohibited for objects to collide with the machine.
5Children are strictly prohibited from approaching the machine to prevent accidents.
6Before replacing the fuse, ensure that the power supply has been cut off.
7After use, please clean the machine without leaving any water droplets or dirt residue.
Produced by our factoryLow temperature water bath oscillator (shaker) andWater bath constant temperature oscillator;Water bath constant temperature shaker;Dual function water bath oscillatorWater bath oscillatorWater bath shakerRotary water bath oscillatorLow temperature water bath oscillatorReciprocating water bath oscillator Dual function water bath constant temperature shaker Rotating water bath constant temperature shaker Reciprocating water bath constant temperature shaker
2The power sockets provided by users should have good grounding measures.
3It is strictly prohibited to move the machine during normal operation.
4It is strictly prohibited for objects to collide with the machine.
5Children are strictly prohibited from approaching the machine to prevent accidents.
6Before replacing the fuse, ensure that the power supply has been cut off.
7After use, please clean the machine without leaving any water droplets or dirt residue.
Produced by our factoryLow temperature water bath oscillator (shaker) andWater bath constant temperature oscillator;Water bath constant temperature shaker;Dual function water bath oscillatorWater bath oscillatorWater bath shakerRotary water bath oscillatorLow temperature water bath oscillatorReciprocating water bath oscillator Dual function water bath constant temperature shaker Rotating water bath constant temperature shaker Reciprocating water bath constant temperature shaker
Online inquiry