MS-1004 RS-485 Four Port Hub
MS-1004 RS-485 Four Port Hub
Product details

    MS-1004 is a specialized RS-485 system designed to solve complex electromagnetic field environments
    Designed RS-485 bus division hub (HUB). This product supports transmission speed
    The maximum rate is 115.2KBPS. In order to ensure the safety and reliability of data communication, RS-485 is connected
    The port adopts optoelectronic isolation technology to prevent lightning surges from entering the converter and equipment
    The photoelectric isolator and 600W surge protection circuit installed can provide a 2500V isolation
    Off voltage can effectively suppress lightning and ESD, while also being effective
    To prevent lightning strikes and common ground interference, the power supply adopts an external switch power supply, which is safe and reliable
    Damn, it's very suitable for outdoor engineering applications.
    In RS-485 working mode, the discrimination circuit used can automatically sense the direction of the data stream
    To enable automatic switching of the control circuit, easily solving RS-485 transmission and reception conversion
    Change the latency issue. The RS-485 interface has a transmission distance greater than 1200 meters and stable performance.
    Widely used in highway toll systems, road monitoring systems, and power collection systems
    Zhong is a high-performance and cost-effective data interface conversion product.
    MS-1004 RS-485 HUB provides star shaped RS-485 bus connection. Each port
    All have short-circuit and open circuit protection. Optoelectronic isolation 2500V, users can easily improve it
    RS-485 bus structure divides network segments to improve communication reliability. When struck by lightning or equipment
    When a backup fault occurs, the problematic network segment will be isolated to ensure the safety of other network segments
    Normal operation. This performance greatly improves the reliability of existing RS-485 networks,
    Effectively shortened the maintenance time of the network. Reasonably utilize MS-1004 RS-485
    HUB can help you design a unique and highly reliable RS-485 system

    1. Interface features: The interface is compatible with EIA/TIA RS-232C and RS-485 standards
    2. Electrical interface: RS-232C interface is a ten digit terminal, RS-485 interface is a ten digit terminal
    Position terminal post
    3. Transmission medium: twisted pair or shielded wire
    4. Working mode: Asynchronous half duplex
    5. Industrial power supply: 9-30VDC/350mA
    6. Signal indication: Seven signal indicator lights for power supply (PWR), transmission (TD), and reception
    (RD)、 Fault (E1-E4)
    7. Isolation degree: Isolation voltage 2500VRMS 500VDC continuous DC/DC module
    8. Transmission rate: 115.2K-300BPS
    9. Protection level: RS-232 interface ± 15KV ESD protection RS-485 interface per line
    600W lightning surge protection
    10. Transmission distance: 0-5 kilometers (115200-300 BPS)
    11. Size: 120mmX72mm x22mm
    12. Operating environment: -25C to 70C, relative humidity of 5% to 95%

    The front panel of MS-1004 has a total of seven indicator lights, and the left and right ends are each connected with ten digit wiring
    Column. The TXD RXD GND on the left end is the RS-232 signal input terminal, 485+485-
    For the RS-485 signal input terminal, GND is the ground. The right end is the 485 signal output port T/
    R1+、T/R1-、T/R2+、T/R2-、T/R3+、T/R3-、T/R4+、T/R4-、
    GND, GND. Note that the GND of the 485 output terminal cannot be connected to the GND of the input terminal.

    The front panel indicator lights of MS-1004 have the following meanings
    PWR power indicator, normally red
    TXD data transmission indicator, normally flashing green, indicating that the data is from INPUT
    Send to OUTPUT ports 1 to 4
    RXD data reception indicator, normally flashing yellow, indicating data from
    OUTPUT ports 1-4 send to INPUT ports E1-E4 ports 1-4
    The fault warning indicator light, when constantly on, indicates that it is connected to ports 1 to 4
    When the RS-485 interface device experiences a short circuit or signal reverse connection, the E1 light and
    Port 1 corresponds to port 4, and E4 lights correspond to port 4. Users can issue a warning based on this fault
    The indicator light identifies the faulty port and its connected faulty device.

    MS-1002 RS-485 Product Ordering Information

    The product includes 1 interface converter, user manual, and certificate of conformity.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!