VIP member
Mineral analyzer Innovat-X ALPHA-4000
Brief introduction: The ore analyzer Innovat-X ALPHA-4000 portable XRF analyzer has become an indispensable equipment in the toolbox of mining sites.
Product details
Details introduction:
Mineral analyzer Innovat-X ALPHA-4000
Mineral analyzer Innovat-X ALPHA-4000 for exploration, discovery, and mining of mineral deposits
XRF is a standard technique for elemental analysis in the mining industry. In the past, miners could only collect samples and send them to the laboratory for analysis, which was expensive and time-consuming. Nowadays, the Innov-X portable XRF analyzer has become an indispensable equipment in the toolbox of mining sites. The Innov-X portable XRF analyzer not only shortens testing time, but also reduces analysis costs. It can perform on-site elemental analysis from phosphorus to uranium. Most mining companies implement sustainable development strategies, hoping to minimize the environmental pollution and health hazards caused by mining. During the smelting process, harmful slag will not only be analyzed, but the analysis results must also be handled in accordance with emergency plans and the Public Right to Know Act (EPCRA). The US Department of Occupational and Health Administration (OSHA) also requires reference to elemental analysis of the air surrounding the filter to control the harm of harmful dust to miners.
Application Fields of the US Portable Environmental Analyzer Innovat-X ALPHA-4000
The Innov-X a-4000 can perform multi-element analysis on various ores and is widely used for the detection and analysis of various ores, as well as for slag refining analysis and archaeological research. All natural ores, slag, rocks, soils, and slurries from phosphorus to uranium, including gold, silver, copper, iron, tin, zinc, nickel, molybdenum, iridium, arsenic, lead, titanium, antimony, vanadium, iodine, sulfur, potassium, phosphate, and uranium ores. The sample being tested can be a tangible object such as a solid, liquid, dust, powder, solid body, fragment, filter material, film layer, etc.
Introduction to the Performance of the US Portable Environmental Analyzer Innovat-X ALPHA-4000
The Innov-X ALPHA-4000 portable ore analyzer is an advanced portable ore analysis system produced by Innov-X Systems in the United States. Innov-X Systems is a globally renowned company specializing in the production and manufacturing of universal and high-performance portable X-ray fluorescence analyzers (XRFs). The Alpha series analyzer provides a portable and versatile handheld X-ray fluorescence analyzer with small size, fast analysis speed, multiple functions, and high accuracy on the current market. This analyzer can be used in any place to ensure material quality, non radioactive materials, and reliable radiation ratio. Multiple selectable filters. It can transmit and read in real-time, and its main components are a small X-ray tube and high-resolution detector.
This analyzer is lightweight (1.6 kg), easy to operate, with one click buttons and long-term fatigue free operation. It can be used in any location from -10 ° C to+50 ° C.
The Innov-X ALPHA-4000 analyzer can be used for on-site analysis of various types of ores. The mature X-ray tube analysis system tested on site has no radioactive isotopes and can quickly conduct ore type research during on-site analysis. It requires low sample requirements, but the test results are accurate and can accurately analyze high concentration samples, avoiding confirmatory laboratory testing.
·Performing in-situ testing: By directly contacting the Inos ore analyzer with the ground, rock surface, reverse circulation (RC) sample, circulating air flow (RAB) sample, or core drilling, users can collect a large amount of data in a short period of time, effectively describing mineral veins, grading minerals, and characterizing potential environmental hazards.
·Assessment of the ore body: The ore grade can be determined on-site without waiting or incurring costs. On site element identification.
·Analysis of milling heads, concentrates, and slag: Conduct rapid and accurate analysis of feed, concentrates, and slag to establish an efficient mining and enrichment process.
·Drawing of mine maps and control of ore grades: The Alpha4000 Inos ore analyzer can guide drilling procedures, manage excavation, and blasting by detecting multiple samples in real-time on-site.
·Mineral exploration: Conducting geochemical measurements on soil, sediment, drilling samples, and other materials in the field for higher accuracy.
·A portable XRF analyzer with good performance in chromium analysis can detect chromium content in ores as low as 25-45ppm.
·Can detect filter media.
·Can analyze dust cloths.
·When analyzing bagged or liquid samples, the testing bench can be conveniently used
Innovat-X ALPHA-4000 PDA technology for portable environmental analyzer in the United States:
The Alpha series plastic analyzer adopts a separate PDA, which is easy to replace, repair, and upgrade. It runs on the Microsoft Windows CE operating system, has a user-friendly, flexible, and upgradable interface, and is equipped with Chinese software for real-time data display. It features color screen, data cable communication, Bluetooth wireless communication, SD card communication, CF card communication, EXCEL format output, TXTL format output, large capacity SD card, large capacity CF card, 128MB standard memory, and can be upgraded to 1Gb flash memory
The Innovat-X ALPHA-4000 XRF data modeling technology for portable environmental analyzer in the United States:
·The X-ray tube light source, multi beam filtering technology, and HP personal digital assistant technology (HP handheld computer) make its measurement range, detection speed, and detection accuracy excellent, and have excellent upgrade potential.
·Advanced and versatile X-ray data modes were utilized - using Compton normalization correction method, which allows for quantitative analysis using "internal standards" without the need for specialized correction.
·Basic parameter analysis: Adopting a semi quantitative analysis method, it is suitable for testing samples with uneven structural density composed of various elements.
·Experimental calibration method: using a "calibration curve" for calibration, allowing the use of user generated calibration curves.
·Equipped with spectral high point recognition software, the spectrum can be viewed on the display screen.
·Compare spectra and complete comparative analysis with reference to built-in standards.
·By updating parameters or changing modes, new experiments can be conducted again using stored test results.
·New elemental components can be added, making it easy to calibrate. Therefore, the Innov-X a-4000 analyzer can meet your current and future needs.
The standard analytical elements configured for the US portable environmental analyzer Innovat-X ALPHA-4000 are:
Standard elements: titanium, vanadium, chromium, manganese, iron, cobalt, nickel, copper, zinc, rubidium, strontium, zirconium, niobium, molybdenum, silver, tin, antimony, tantalum, hafnium, tungsten, lead, bismuth.
According to the different configurations of different analyzers, the focus of instrument detection will also vary. Please contact our company to select a suitable metal analysis instrument based on your specific requirements for metal element analysis.
Precautions for sample preparation of the US portable environmental analyzer Innovat-X ALPHA-4000:
·The quality of sample preparation greatly determines the accuracy of test results when using a portable X-ray fluorescence analyzer.
·EPA Method 6200 is mainly used as a reference standard for on-site testing of X-ray fluorescence analyzers at any time, rather than for testing prepared samples.
·Of course, the sample preparation work also varies depending on the testing purpose. For example, when conducting quantitative on-site screening, conducting on-site testing is generally sufficient. At this point, you can choose to analyze the sample in a plastic bag or directly on the ground. Field testing can immediately provide a series of important information, which helps to quickly understand the site and discover "hotspot" areas.
·If you want to obtain more quantitative test results or directly compare them with certain laboratory analyses (such as AA or ICP), you need to pre cultivate the sample in a sampling cup to be dry and homogeneous. If you want to conduct an ideal comparative sampling test, a good method is to analyze the same sample analyzed by an X-ray fluorescence analyzer in the laboratory.
·For details on sample preparation precautions, please refer to the "Sample Preparation" section on page 8 of EPA Method 6200.
·When conducting laboratory analysis, it is essential to use the complete decomposition method.
Basic specifications of the US portable environmental analyzer Innovat-X ALPHA-4000
|
Specification
|
|
Weight: 2.625 lbs (base weight) 3.375 lbs (1.6 kg) with battery on
|
|
X-ray: X-ray tube, W positive electrode, 10-40kV, 10-50uA, five selectable filters
|
|
Strong: Especially for detecting chromium, chlorine, and phosphorus elements
|
|
Detector: Silicon Pin diode detector,<230 eV FWHM on 5.95keV alpha line, temperature range: -10 ℃ to 50 ℃
|
|
Operation: Trigger or start/stop button, one touch trigger or select "deadman" trigger, or choose to control from an external computer
|
|
Power supply: rechargeable lithium battery (including charger), equipped with power analyzer and iPAQ, AC converter (optional)
|
|
Battery usage time: 8 hours (typical working cycle), 4 hours of continuous operation (with the tube in use)
|
|
Element quantity: includes standard packaging of 22 elements
|
|
Standard elements: titanium, vanadium, chromium, manganese, iron, cobalt, nickel, copper, zinc, rubidium, strontium, zirconium, niobium, molybdenum, silver, tin, antimony, tantalum, hafnium, tungsten, lead, bismuth.
|
|
Display screen: Color, high-resolution touch screen, adjustable brightness to make it visible in all surrounding lighting environments
|
|
Data display: Focused on ppm, spectral and/or peak intensity (count rate) or user-defined units, depending on the selected software mode
|
|
Memory and data storage: It can store up to 20000 spectral test results, and upgrading to a 1Gb flash card can store more than 100000 test results. It has a standard memory of 128 MB
|
|
Processor: Intel 400MHz StrongArm processor
|
|
Operating System: Microsoft Windows CE (Mobile System) or Windows (PC based). Software mode: Accurate chemical quantitative analysis; Quick classification of PVC or brominated plastics (2-second test)
|
Online inquiry