Detailed information on SNC2400-AIR atmospheric environment multi gas analyzer (mobile):
SNC2400-AIR Atmospheric Environment Multi Gas Analyzer (Mobile)
Overview of Multi Gas Analyzer for Atmospheric Environment (Mobile)
Using imported high-quality industrial sensorsThe principle isElectrochemistry and photometerVarious types such as optoelectronics, is currently the most economical and practicalatmosphereInstruments for pollutants.Mainly used for detecting landfills, incineration plants, solid waste disposal sitesDetection of respiratory and excretory gases in human animals、Hospital waste and medical wasteGrid based, big data based, cloud based, IoT based, and acute air pollutant gas analysis and detection in environments such as places, chemical parks, ports, docks, and storage warehouses for detecting hazardous materials.
Alias:
Atmospheric grid monitoring instrument, atmospheric environment monitoring instrument, multi parameter gas sampling instrument, grid atmospheric environment detection instrument, micro atmospheric monitoring station, small atmospheric environment monitoring device, carbon monoxide monitoring instrument, sulfur dioxide detector, nitrogen dioxide collector, ozone analyzerPM2.5Monitoring instrumentPM10Monitoring instrument, temperature transmitter, humidity monitoring instrument
Application scenarios
Atmospheric environment monitoring stations, environmental management, smart cities, data collection, Internet of Things, etc.
Application
Indoor air quality testing, suitable for air index testing in offices and other public places
Quality assessment of air conditioning system
Quality Management and Application Effect Measurement of Air Purification Products
Acceptance of decoration engineering and detection of total organic steam content
Pollution source environmental testing
Environmental air quality supervision
Environmental Protection Department Air Quality Index Inspection
chemical industrial park/Construction siteAir toxicity testing
grid-basedAir quality in public safety incidentspollutantQuick testing
Main Features
The parameters to be detected can be selected according to the actual situation, and multiple gases can be detected simultaneously
Customizable, expandable to add meteorological parameters, reserved5-8 ports
Convenient backpack, capable of completing on-site tasksEmergency testingLaboratory testing requires
Odor detection system based on "gas sensor output signal analysis technology"
Immediate on-site inspection and analysisAtmospheric Environmentgasconcentration content
can be increasedVOC、Highly toxic gases such as non methane hydrocarbons, hydrogen chloride, hydrogen fluoride, and hydrogen cyanide
Detection based on Smart Logic
Support automatic cleaning sensor functionCapacitive touch screen, capable of supporting 5-point touch
Support separate control of backlight, can turn off backlight to save power consumption
Supports standard HDMI interface input, LAN port, and remotely upgradable software system
Industrial control computer, supporting Win7 system, capable of storing data and exporting tables
Grid based, IoT, and cloud based big data for pollutant detection, warning, and traceability
execution standard
Methods for Air and Waste Gas Detection and Analysis
GB 3095-1996<Environmental Air Quality Standard>
GB 16297-1996 Comprehensive Emission Standards for Air Pollutants
GB/T 18883-2002 Indoor Air Quality Standard
technical indicators
Main parameters |
rangescope |
resolution |
mistake poor |
Wen degree |
-40℃~+70℃ |
0.1℃/ |
±0.2℃ |
wet degree |
0~100% |
0.1% |
±3% |
wind fast |
0~70 m /s |
0.1 m /s |
≤±2% |
wind to, toward, at, facing |
16 azimuth (360 º) |
0.1 º |
±3% |
atmospheric pressure |
50~110Kpa |
0.1Kpa |
±0.5kpa |
total radiation |
0~2000W/m2 |
1W/m2 |
±3% |
carbon dioxide |
0-5000ppm |
0.01ppm |
≤±2% |
nitrogen oxides |
01/50/100/300ppm |
0.001/0.01ppm |
≤±2% |
nitric oxide |
050/300ppm |
0.01ppm |
≤±2% |
carbon monoxide |
0-1/50ppm |
0.001/0.01ppm |
≤±2% |
sulfur dioxide |
01/20 ppm |
0.001/0.01ppm |
≤±2% |
nitrogen dioxide |
0-1/50/1000/4000ppm |
0.001/0.01/1ppm |
≤±2% |
Organic gas (TVOC) |
040/100ppm |
0.001/0.01ppm |
≤±2% |
Photochemical oxidant (O3) |
01/10/100ppm |
0.001/0.01ppm |
≤±2% |
Total suspended particulate matter TSP |
0-100mg/M3 |
0.01ppm |
≤±2% |
Tetrahydrothiophene |
0-12ppm |
0.01 ppm |
≤±2% |
chlorine qi |
0-50ppm |
0.01 ppm |
≤±2% |
fluorine qi |
0-1ppm |
0.01 ppm |
≤±2% |
iodine qi |
0-1ppm |
0.01 ppm |
≤±2% |
ammonia qi |
0-100ppm |
0.1 ppm |
≤±2% |
hydrogen chloride |
0-30ppm |
0.01 ppm |
≤±2% |
hydrogen fluoride |
0-10ppm |
0.01 ppm |
≤±2% |
hydrogen cyanide |
0-30ppm |
0.01 ppm |
≤±2% |
hydrogen sulfide |
0-100ppm |
0.1 ppm |
≤±2% |
Arsenic hydride |
0-1ppm |
0.01 ppm |
≤±2% |
Hydrogen selenide |
0-10ppm |
0.1 ppm |
≤±2% |
phosphine |
0-20ppm |
0.01 ppm |
≤±2% |
light qi |
0-20ppm |
0.01 ppm |
≤±2% |
VOCs |
02050 ppm |
0.001/0.01ppm |
≤±2% |
A aldehyde |
0-10ppm |
0.01 ppm |
≤±2% |
ally ammonia |
0-1ppm |
0.01ppm |
≤±2% |
acrylonitrile |
0-50ppm |
0.01ppm |
≤±2% |
DMF |
0-50ppm |
0.01ppm |
≤±2% |
carbon disulfide |
0-50ppm |
0.01ppm |
≤±2% |
Ethylene Oxide |
0-50ppm |
0.01ppm |
≤±2% |
germanium alkane |
0-20ppm |
0.01ppm |
≤±2% |
Overall dimensions |
(L360×W260×H180)mm |
response time |
≤10s |
Total weight |
3kg |
power supply |
DC 6-12V |
power waste |
≤10W |
gas flow rate |
1000mL/min |
Operating Temperature |
-30~50℃ |
Protection level |
IP65 |
Not listed in the table, please consult sales for customization | |||
Model Series |
Technical Specifications |
Remarks |
SNC2000-AIR |
NOx、CO、CO2、O3、PM10 |
Enterprise, environmental protection, energy conservation |
SNC2100-AIR |
碳氢、 CO、CO2、NOx、O2、SO2 |
Enterprise, environmental protection, energy conservation |
SNC2200-AIR |
VOC、CO、O3、NOx、SO2、 wind speed and direction |
Enterprise, environmental protection, energy conservation |
SNC2300-AIR |
Non methane total hydrocarbons CO、O3、NOx、SO2、 wind speed and direction |
Enterprise, environmental protection, energy conservation |
SNC2400-AIR |
HF、O3、NOx、SO2、PM2.5/10 |
Enterprise, environmental protection, energy conservation |
SNC2500-AIR |
HCN、O3、NOx、SO2、 Wind speed PM2.5 |
Enterprise, environmental protection, energy conservation |
SNC2600-AIR |
VOC、O3、NOx、SO2、TSP |
Enterprise, environmental protection, energy conservation |
Customized according to customer requirements | ||