Norton K6-C multifunctional coating thickness gaugeMulti functional, more comprehensive than the current coating thickness gauges on the market, with multiple optional models to meet different functional measurements.
The Norton K6-C multifunctional coating thickness gauge has the following functions:
1. Electroplated coatings (zinc, chromium, nickel, cadmium, silver, tin, and other coatings) on steel products.
2. Electroplating layers (zinc, chromium, nickel, cadmium, silver, tin, and other coatings) on non-ferrous metal products.
3. Coatings, paints, enamels, powders, mastics, and other insulation coatings on steel products.
4. Anodized oxide coatings, phosphide coatings, and other insulation coatings for black and non-ferrous metals.
5. Special insulation coating and thick metal coating, electroplating coating.
6. Internal surface coating of pipelines and cylindrical products.
7. Copper foil for printed circuit boards.
8. Electroplating coatings on thin plates and insulation materials made of colored conductor materials.
9. Two layer component coating.
10. Concrete protective layer and determination of steel reinforcement position in concrete.
11. Wall thickness measurement of large thin glass and carbon fiber reinforced plastic products with entrances at one end and both ends (measurement during production and delivery).
12. Measure the depth of the groove and evaluate the surface roughness after sandblasting or gravel impact.
13. Control weather conditions (air humidity, air and metal surface temperature, dew point temperature, and measurement of temperature change parameters).
The Norton K6-C multifunctional coating thickness gauge almost includes the functions of the current * * coating thickness gauge on the market, and more functions can achieve a better measurement experience. If you need a sturdy instrument, the Czech NortonThe coating thickness gauge can meet your needs.
Norton K6-C multifunctional coating thickness gaugeProduct advantages:
1. Automatically calculate the upper and lower limits of the average band.
2. The measurement results are displayed in the statistical sample.
3. Scan mode with upper and lower limit values.
4. Diagonal2.4inchTFTColor display screen with built-in lithium battery.
5. Ergonomic shock resistant design with rubber protection at the corners.
6The keyboard comes with function keys that can be adjusted according to the device's working mode; The user interface is user-friendly and intuitive.
7. Additional modes and device settings.
8. Ergonomically designed small-sized wear-resistant sensor expansion component.
9. Sensors that support multiple calibration features (forPH3Series probes, * multiple supports6One; ForNF-GProbe, * multiple supports4One; ForF-GProbe, * multiple supports2A).
Norton K6-C multifunctional coating thickness gaugeBasic technical characteristics:
measurement range
Measuring range:0.5 µm–120 mm
Number of sensors
Customers can choose for themselves
calibration method
·Additional single point calibration
·Two-point calibration
·Single point (with automatic multiplication correction)
Computer connection
USB 2.0 channel
temperature range
·For devices:-30……+40℃
·For sensors:-40……+50℃
For high-temperature sensors, the temperature can reach up to+350℃)
power supply
Built in lithium-ion battery,3.7–4.2 V, 1500–1700 mAh
Overall dimensions
60×125×25mm
Weight of electronic unit
120g
Continuous working hours
More than 12 hours
Charging time
4 hours
warranty period
instrument main unit-3year
sensor-2year
Deliver components
Instrument host and sensors (quantity and model can be selected by customers)
charger
Coating thickness and substrate reference sample (based on the selected sensor)
mini-USB —USB AType computer connection cable
Operation Manual
Shockproof packaging box
Norton K6-C multifunctional coating thickness gaugeTechnical parameters of sensors
Magnetic induction and eddy current combined probe
FNF
Used to measure the thickness of coatings, powder layers, plastic layers, glazes, and other non-conductive coatings on conductive ferromagnetic and non-magnetic substrates.
Technical features:
Measuring range:0-1500μm (1.5mm)
Measurement accuracy:±(0.015T + 1)μm
Diameter of measurement area:6mm
*Small substrate diameter: convex surface/Concave surface Φ4mm/Φ12mm
Size: Φ21×90mm
Magnetic induction probe
For the measurement of coating thickness on ferromagnetic substrates,K6-CofFThe series probe includes a calibration characteristic curve.
F0
Used for measuring electroplating layers (zinc, chromium, cadmium, etc.) and insulation layers (plastic, paint, etc.) on small-sized components (small curvature radius), as well as hard to reach areas on ferromagnetic materials.
Technical features:
Measuring range:0-300μm(0.3mm)
Measurement accuracy: ±(0.02T+1) µm
Diameter of measurement area: Φ3mm
Small diameter of substrate: Φ4.5mm(Φ1 mm)
Size: Φ9 ×34 mm
Note: Pen type probe; Fixed measurement system; The small diameter of the measurement area is completely unaffected by the conductivity of the coating.
F0/90
Used for measuring electroplating layers (zinc, chromium, cadmium, etc.) and insulation layers (plastic, paint, etc.) on small-sized components (small curvature radius), as well as hard to reach areas on ferromagnetic materials.
Technical features:
Measuring range:0-300μm(0.3mm)
Measurement accuracy: ±(0.02T+1) µm
Diameter of measurement area: Φ3mm
Small diameter of substrate: Φ4.5mm (Φ1 mm)
Size: Φ20×127 mm
F1
Metal coatings are particularly suitable for measuring electroplating layers (zinc, chromium, cadmium, etc.) and insulation coatings (plastic, paint, etc.) on small-sized components made of ferromagnetic materials.
Technical features:
Measuring range:0-500μm(0.5mm)
Measurement accuracy:±(0.02T+1) µm
Diameter of measurement area: Φ4mm
Small diameter of substrate: Φ4.5mm (Φ1 mm)
Size: Φ9 ×65 mm
Note: The wear-resistant probe equipped with a spring measurement system is used to control the electroplating coating and is completely unaffected by the coating conductivity.
F2
Used for measuring non-conductive coatings (coatings, powder coatings, anodized coatings, etc.) and conductive non-magnetic coatings (zinc, chromium, etc.) on ferromagnetic materials. Measuring range up to2Millimeters.
Technical features:
Measuring range:0-2000μm(2mm)
Measurement accuracy:±0.02T µm
Diameter of measurement area: Φ6mm
Small diameter of substrate: Φ9mm (Φ1.5 mm)
Size: Φ19 ×83 mm
Note: Probe equipped with spring measurement system. Use hard metal material as the probe front end to prevent probe wear.
F3
Used for measuring non-conductive coatings (coatings, powder coatings, anodized coatings, etc.) and conductive non-magnetic coatings (zinc, chromium, etc.) on ferromagnetic materials. Measuring range up to6Millimeters.
Technical features:
Measuring range:0-6000μm(6mm)
Measurement accuracy:±0.02Tμm
Diameter of measurement area: Φ8mm
Small diameter of substrate: Φ10.5mm (Φ2.5 mm)
Size: Φ19 ×83 mm
Note: The probe with a spring measurement system is used for thick coating measurement.
F4
Measure the thickness of asphalt, plastic, metal foil, refractory materials, and other non ferromagnetic coatings (including specially designed coatings) on rough steel substrate surfaces.
Technical features:
Measuring range:0-8mm
Measurement accuracy within the given range:0-6 mm:≤±(0.015T + 0.01)mm;6-8mm:≤±0.02T
*Small substrate diameter: internal/Outer diameter Φ5mm/Φ18.5mm
Diameter of measurement area:12mm
Size: Φ15×49mm
F5
Measure the thickness of asphalt, plastic, metal foil, refractory materials, and other non ferromagnetic coatings (including specially designed coatings) on rough steel substrate surfaces.
Technical features:
Measuring range:0-10mm
Measurement accuracy within the given range:0-8 mm:≤±(0.015T + 0.01)mm;8-10mm:≤±0.02T
*Small substrate diameter: internal/Outer diameter Φ7/Φ57mm
Diameter of measurement area:17mm
Size: Φ23×58mm
Eddy current probe
For the measurement of coating thickness on non-magnetic substrates,K6-CofNFThe series probe includes a calibration characteristic curve.
NF0
Used for measuring non-conductive coatings (coatings, powder coatings, anodized coatings, etc.) and conductive non-magnetic coatings (tin, zinc, etc.) on workpieces made of conductive non ferromagnetic materials. Measuring range up to0.5Millimeters.
Technical features:
Measuring range:0-500μm(0.5mm)
Measurement accuracy: ±(0.02T+1) µm
Diameter of measurement area: Φ1.5mm
Size: Φ6 ×35mm
Note: The combination of the probe and spring measurement system ensures the high strength and rigidity of the probe through the use of modern materials.
NF1
Used for measuring non-conductive coatings (coatings, powder coatings, anodized coatings, etc.) and conductive non-magnetic coatings (tin, zinc, etc.) on workpieces made of conductive non ferromagnetic materials. Measuring range up to2Millimeters.
Technical features:
Measuring range:0-2000μm(2mm)
Measurement accuracy: ±0.02T µm
Diameter of measurement area: Φ4.7mm
Size: Φ6 ×35mm
Note: The combination of the probe and spring measurement system ensures the high strength and rigidity of the probe through the use of modern materials.
NF2
Used for measuring thicker non-conductive coatings on metal substrates.
Technical features:
Measuring range:0-15000μm(15mm)
Measurement accuracy:±0.02T µm
Diameter of measurement area: Φ20mm
Small diameter of substrate: Φ12mm(Φ5 mm)
Size: Φ15 ×85mm
NF3
Used for measuring thicker non-conductive coatings on metal substrates.
Technical features:
Measuring range:0-30mm
Measurement accuracy:±0.02T µm
Diameter of measurement area: Φ40mm
Small diameter of substrate: Φ45mm(Φ15mm)
Size: Φ23 ×88mm
NF4
Used for measuring thicker non-conductive coatings on metal substrates.
Technical features:
Measuring range:0-70mm
Measurement accuracy:0-40mm:≤(1%±0.1);40-70mm: 2%
Diameter of measurement area: Φ90mm
Small diameter of substrate: Φ270mm(Φ80mm)
Size: Φ80×60mm
Note: The probe is combined with the spring measurement system. Capable of withstanding high temperatures and displaying stability in the on-site work environment.
Phase eddy current measurement probe
K6-C'sPHThe series probe includes a "coating/Matrix characteristic curve.
PH1
Used for measuring electrolytic nickel, zinc, and other electroplated coatings on steel substrates.
Technical features:
Measuring range:0-120μm
Measurement accuracy: ≤±(0.03T + 1) µm
Diameter of measurement area: Φ4.7mm
Small diameter of substrate: Φ1mm
Size: Φ12 ×40mm
Note: The electroplating coating under the insulation layer can be controlled.
PH3
Used for measuring electroplated coatings (zinc, chromium, nickel, copper, cadmium, etc.).
Technical features:PH3-0,2 || PH3-1,8
Measuring range:0-120Mm || 40 μm
Measurement accuracy: ≤±(0.03T + 1) ||≤±(0.03T +1) µm
Diameter of measurement area: Φ1 mm ||Φ1mm
Small diameter of substrate: Φ1 mm ||Φ75mm
Size: Φ6 ×50mm ||Φ6×50mm
Note: The electroplating coating under the insulation layer can be controlled.
**Probe
F×P,NF×P
Used for measuring ferromagnetism(F×P)And non ferromagnetic(NF×P)Inside pipes made of materials.
Technical features:
Measuring range:0-2 μm
Measurement accuracy: ≤±( 0.02T+ 0.001)Mm
Diameter of measurement area: Φ4.7mm
Small diameter of pipeline: Φ14mm
Note: The probe design has a manual operation mode. Openings on both sides of the pipeline. The use of wear-resistant probes depends on the diameter and length of the pipeline.
FR1
Used to measure the depth and position of reinforcing bars in concrete.
Technical features:
Measuring range:0-70 mm
Measurement accuracy: ≤±(0.05T + 0.1) mm
Diameter of steel bar: Φ3-40 mm
Concrete size:100x30x50mm
Note: Applicable to a wide range of concrete thickness and steel bar diameter.
FR2
Used for measuring thicker (up to) on ferromagnetic surfaces120 mm)Protective coating.
Technical features:
Measuring range:1-120 mm
Measurement accuracy: ≤±(0.05T + 0.1) mm
Size:180x30x50mm
R
Used for measuring roughness before painting and after sandblasting.
Technical features:
Measuring range:3-300 µ m
Measurement accuracy: ≤±0.02 Rz
Size: Φ12×45mm
THDC
Used to measure metal surface temperature, air temperature, relative air humidity, dew point temperature, and calculate the difference between metal surface temperature and dew point temperature (to check the working condition during the painting process of metal products).
Note: WhenTHDCWhen the probe is connected to the device, the display will show the data shown in the above figure.
THD
Used for measuring air temperature, humidity, and dew point during the painting process.
|
Technical Characteristics 1Measurement range: Air temperature:-10°C – +40°C Air humidity:5-90% Dew point temperature:-15°C – 40°C
2Measurement accuracy: Air temperature: ±1°C Air humidity: ≤±5% Dew point temperature: ≤±2°C
Size: Φ15×120 mm Note: Integrated probe with wide measurement range. |
|