Designed for industrial and materials science applications
The BX53M series adopts a modular design, providing diverse solutions for a wide range of materials science and industrial applications. According to different applications in industry and materials science, BX53 can be combined into microscopes for various applications such as reflection microscopes, transmission and reflection microscopes, infrared microscopes, polarizing microscopes, etc.
High * * microscopic observation and convenient microscopic operation
user friendliness
Simple and guided microscope operation settings make it easier for users to adjust and copy system settings.
functionality
BX53M is designed for traditional industrial microscope inspection and has expanded its functionality to meet the requirements of a wider range of applications and inspection techniques.
Precise optical components
Olympus Corporation has a long history of producing high-quality optical components, with excellent image quality whether viewed through an eyepiece or a monitor.
Comprehensive customizability
Modular design allows users to flexibly build systems that meet their specific requirements.
Intuitive microscope control is comfortable and easy to use
Microscopic examination tasks often require a long time to adjust microscope settings, acquire images, and perform necessary measurements to obtain satisfactory reports. Users sometimes need to invest time and money to complete microscope training, or only learn a small part of the full functions of the microscope before starting work.
The BX53M simplifies complex microscopic examination tasks through its excellent design and convenient control functions. Users do not need long training to master most of the functions of the microscope. The convenient and comfortable operation of BX53M also improves the reproducibility of images, greatly reducing human errors.
2.1 Encoding Hardware: It is easy to restore microscope settings
The BX53M adopts a new encoding function that integrates the hardware settings of the microscope with the Olympus Stream image analysis software. The observation method, illumination intensity, and objective position are all recorded in the software and/or manual controller. The encoding function enables the microscope settings to be automatically saved with each image, making it easier to restore settings and provide document records for reports. Not only does it save the operator's time, but it also greatly reduces the probability of using incorrect settings. The current observation settings are always clearly displayed on the manual controller and software.
2.2 Intelligent Light Intensity Management: * * Zhi Lighting
During initial installation, the lighting intensity can be adjusted to match the specific hardware configuration of the encoder illumination and/or encoder objective converter.
2.3 Convenient and user-friendly operation
Humanization is crucial for all users. Both single machine microscope users and microscope system users with integrated Olympus Stream image analysis software can benefit from a user-friendly manual controller that can clearly display the location of microscope encoded hardware. Simple manual switch allows users to focus their time on the sample itself and the required inspections to be carried out.
3. * * Advanced imaging
BX53M, in addition to the traditional contrast method used for conventional microscopy inspection, can also solve many of the difficulties encountered in defect detection when using traditional contrast method for inspection in the past.
3.1 MIX Combination Observation: Display Previously Invisible Images
The MIX combination observation technology of BX53M combines bright field and dark field illumination methods. It is very useful for highlighting defects and distinguishing between raised and depressed surfaces.
3.2 Instant Puzzle (MIA): Easily move the stage for panoramic photography
Now, simply moving the XY knob on the manual stage allows for convenient and quick image stitching, eliminating the need for an electric stage.
The Olympus Stream software uses pattern recognition technology to generate panoramic images, providing users with a wider field of view than a single image.
3.3 Easy Implementation of Ultra Depth of Field Image (EFI) Questions
The depth of field extended imaging (EFI) function of Olympus Stream software can capture sample images with a height exceeding the depth of focus of the objective lens, and overlay them together to create * * super depth of field images. EFI can be performed using manual or electric Z-axis mechanisms, and * * height maps can be created to easily identify structures. You can also create EFI images offline using Stream desktop version.
4. The long history of optical technology
Olympus Corporation has a long history of developing high-quality optical instruments, creating multiple records of optical quality and ensuring the measurement accuracy of microscopes.
4.1 LED Lighting
BX53M provides a white LED light source for both reflected and transmitted light illumination. LED provides long-lasting illumination and is an ideal tool for materials science testing applications.
4.2 Automatic Calibration
Similar to digital microscopes, automatic calibration can also be implemented when using Olympus Stream software. Can obtain more reliable measurement results.
BX53MSpecifications (for reflection and reflection)/Transmitting light combination
|
|
BX53MTRF-S |
BX53MRF-S |
BXFM |
|
|
optical system |
UIS2Optical system (infinite correction) |
|||
|
Microscope frame |
lighting |
reflection/transmission |
reflection |
|
|
FOCUS |
trip:25 mm |
trip:30 mm |
||
|
**Large sample height |
35 mm (Excluding height adapter) |
65 mm (Excluding height adapter) |
Depends on installation configuration |
|
|
observing tube |
wide-fieldFN22 |
Inverted images: binocular, trinocular, tilted binocular |
||
|
Ultra wide field of viewFN26.5 |
Inverted image: Three eyes |
|||
|
Reflected light illumination |
Conventional observation techniques |
BX3M-RLAS-S |
||
|
- |
U-KMAS |
|||
|
fluorescence |
BX3M-URAS-S |
|||
|
Transmitted light |
white lightLED |
- |
||
|
Nosepiece |
used forBF |
Six holes, centering six holes, seven holes, encoding five holes (optional electric objective lens converter) |
||
|
used forBF/DF |
Six holes, five holes, centering five holes, encoding five holes (optional electric objective lens converter) |
|||
|
stage |
Coaxial left-hand (right-hand) operation of the stage: |
- |
||
|
weight |
about18.3 kg |
about15.8 kg |
about11.1 kg |
|