product description
The PE60 pressure/differential pressure loosening controller provides 5 relay outputs and 1 analog output, which are used for automatic pressure detection, action control, water level alarm, etc. of equipment, achieving remote pressure measurement and control. When high-frequency switching or high switching accuracy is required.

characteristic
14 segment LED display
● Key programming, easy to operate
5 independent 3A relay control points
● switchable 4-20mA and 0-10V output formats
Record the highest pressure during the work process (can be cleared by pressing the button)
● Supports four installation methods: base plate, guide rail, panel, and flexible joint
● Support 0-99s delay action setting
Technical Parameter
| output data | |
| Accuracy: | ≤±0.25%FS;≤±0.5%FS |
| Repeatability: | ≤±0.2%FS |
| Display: | Full of 4 digits, 0.56-inch 14 segment digital display |
| Temperature drift: | ≤± 0.03% FS/℃ (zero/full degree) |
| analog output | |
| Current type: | 4mA~20mA DC, Load resistance ≤ 560 Ω |
| Voltage type: | 0V~10V DC, Load resistance ≥ 10k Ω |
| Switching Output | |
| Type: | 5-way relay, normally open and normally closed contacts |
| Switching voltage: | ≤277V AC; ≤30V DC |
| Switching current: | ≤3A |
| Response time: | <1ms |
| Switch point setting: | 1.5%FS~99%FS |
| Return difference setting: | 1%FS~10%FS |
| life: | ≥ 10 million cycles/minimum load; ≥ 100000 times/maximum load |
| Switch delay: | 0s~99s |
| environmental condition | |
| Working temperature: | -25℃~65℃ / -13℉~149℉ |
| Relative humidity: | 0%~85% |
| Storage temperature: | -40℃~70℃ / -40℉~158℉ |
| Medium temperature: | -20℃~80℃ / -50℉~176℉ |
| Electromagnetic compatibility: | LVD 2006/95/EC&EMC 2004/108/EC |
| Vibration: | ≤5g/10Hz…500Hz(IEC 60068-2- 6-2007) |
| to attack: | ≤10g/11ms(IEC 60068-2-27-2008) |
| input data | |
| Power supply: | (220±44)V AC/ 22V~32V DC |
| Range: | 0kPa~10kPa… 60MPa |
| Overvoltage: | 1.5 times full range pressure |
| Static pressure: | 20MPa |
Exterior structure (unit: mm)

PE60A pressure controller

PE60B differential pressure controller
Installation method

Wall mounted installation

35mm track installation

PANEL MOUNT

| KAP60A pressure | ||
| Standard Range Code Table (Unit: mbar&bar) | ||
| Standard range | Gauge pressure code | Absolute pressure code |
| 0…100mbar | GB0,1 | AB0,1 |
| 0…1bar | GB1 | AB1 |
| 0…2.5bar | GB2.5 | AB2.5 |
| 0…4bar | GB4 | AB4 |
| 0…6bar | GB6 | AB6 |
| 0…10bar | GB10 | AB10 |
| 0…20bar | GB20 | AB20 |
| 0…40bar | GB40 | AB40 |
| 0…60bar | GB60 | AB60 |
| 0…100bar | GB100 | AB100 |
| 0…160bar | GB160 | AB160 |
| 0…200bar | GB200 | AB200 |
| 0…300bar | GB300 | AB300 |
| 0…400bar | GB400 | AB400 |
| 0…500bar | GB500 | AB500 |
| 0…600bar | GB600 | AB600 |
| KAP60B differential pressure | |
| Standard Range Code Table (Unit: mbar&bar) | |
| Standard range | Differential pressure code |
| 0…350mbar | DB0,35 |
| 0…1bar | DB1 |
| 0…2.5bar | DB2.5 |
| 0…4bar | DB4 |
| 0…6bar | DB6 |
| 0…10bar | DB10 |
| 0…15bar | DB15 |
| 0…20bar | DB20 |
| 0…25bar | DB25 |
| 0…30bar | DB30 |
| 0…35bar | DB35 |
Model Selection Table
| PE60A- | Intelligent pressure controller | |||||||
| PE60B- | Intelligent pressure controller | |||||||
| range | ||||||||
| Gauge pressure (see range code table for range) | ||||||||
| Absolute pressure (see range code table for range) | ||||||||
| Differential pressure (see range code table for range) | ||||||||
| Power supply mode | ||||||||
| 22V~32V DC | ||||||||
| 220V AC | ||||||||
| output form | ||||||||
| Five relay outputs+analog output (4mA~20mA DC) | ||||||||
| Five relay outputs+analog output (4mA~20mA DC/0V~10V DC multiplexed) | ||||||||
| Process connection | ||||||||
| G1/2 external thread | ||||||||
| M20 × 1.5 external thread | ||||||||
| G1/4 internal thread pressure interface (KAP60B) | ||||||||
| The selection form for appeal does not include selection codes. If you need a code, please contact us or fill in your information | ||||||||