PEC-H07 Integrated Current Voltage Transformer Error Tester
PEC-H07 Integrated Current Voltage Transformer Error Tester
Product details

1.jpg

This machine adopts the principle of small signal measurement, and a single instrument can complete the error testing of current and voltage transformers, making it convenient for on-site calibration of measuring devices.

Use a power supply with a frequency close to the power frequency for testing to prevent interference.

Wide measurement range.

Directly integrate on-site data and determine whether it is qualified or unqualified.

One measurement and display of the actual regulation point and error (angle difference, ratio difference) of the current and voltage transformer under any load.

Measuring voltage transformers that meet the requirements of national regulations20-120%Detection of point errors (angle difference, ratio difference) in the regulations.

Detect the transformation ratio and polarity of the voltage transformer.

Intelligent judgment of external wiring status, indicating wiring errors, transformation ratios, polarity errors, etc.

It can store and print various measurement data on site, making it convenient for users to query.

The instrument passes the standardUSBThe interface facilitates the connection and transmission of data with computers.




2.jpg

CTVariable ratio range

5A/525000A/5A(5A/15000A/1A)

Error measurement range

5A/5A5000A/5A(5A/15000A/1A)

Tested current transformer

Accuracy range:1.0 0.50.5S0.2and0.2S

accuracy

±0.05%

PTError measurement range

Primary voltage:3-110KV/3 Secondary voltage:100V,100V/3

accuracy

±0.05%

DC resistance

0.0-0.1Ω ±3% 0.1-50Ω ±1%

CTsecondary load

1Ω-25Ω ±2%

Ptsecondary load

1KV-500KV ±2%

working conditions

AC 220V 10%/50Hz 2%

ambient temperature

0-40

ambient humidity

25<85%

Total weight

5Kg