Super measurement performance, high precision for pressure, differential pressure, liquid level, and flow measurement: digital accuracy+(-) 0.05%; Sim
Product details
The key raw materials, components, and parts of the PTH1151/3351DP differential pressure transmitter are all imported or jointly produced, and the entire machine has undergone strict assembly and testing. This product features advanced design principles, complete variety and specifications, and easy installation and use. Due to the complete integration of the structural advantages of the two most popular and widely used transmitters in China (Rosemount 3051 and Yokogawa EJA) in terms of appearance, this model provides users with a refreshing feeling and has strong versatility and substitutability. In order to adapt to the continuous improvement and development of domestic automation level, this series of products not only has a compact and exquisite design, but also introduces intelligent functions with HART fieldbus protocol.
Technical Parameter
  • Target audience: liquids, gases; And steam
  • Power supply voltage: 12-36V DC, standard value 24VDC;
  • Output signal: 4-20mADC; (Special for four wire 220V AC power supply 0-10mA DC output)
  • Environmental temperature: -25~70 ℃ (for general transmitters), -15~70 ℃ (with on-site indicators)
  • Measurement temperature: -40-104 ℃, flange filled with silicone oil -40-104 ℃, filled with high-temperature silicone oil 15-315 ℃
  • Storage temperature: -40-100 ℃;
  • Relative temperature: 0-100% RH
  • Protection level: d Ⅱ BT4, ia Ⅱ CT5;
  • Power supply impact: less than ± 0.005%/V of the output range;
  • Vibration effect: Vibration at 200Hz in any direction causes an error of 0.05%/g of the maximum range (micro differential pressure of 0.25%/g);
  • Installation position impact: When the working diaphragm is not installed vertically, a zero position error of no more than 0.24Pa may occur, which can be eliminated by adjusting the zero position and has no effect on the range;
  • Stability: not exceeding the accuracy of the transmitter within six months;
  • Indicator: Linear indicator 0-100%; 3-1/2 digit LCD display
  • Range and zero position: externally continuously adjustable
  • Positive and negative migration: The maximum positive migration amount is 500%, and the maximum negative migration amount is 600%
  • Material: Isolation membrane: 316L stainless steel, Hastelloy-C, Monel alloy, tantalum
    Exhaust/drain valve: 316L stainless steel, Hastelloy-C, Monel alloy
    Flanges and fittings: 316L stainless steel, Hastelloy-C, Monel alloy
    O-ring: Fluororubber
    Filling fluid: silicone oil inert oil
    Bolt: 316L stainless steel
    Electronic casing: low copper aluminum alloy
Product Selection
PTH1151/3351DP differential pressure transmitter
describe
Range of measurement 2 0~0.125-1.5KPa
3 0~1.3-7.5KPa
4 0~6.2-37.4 KPa
5 0~31.1-186.8 KPa
6 0~117-690 KPa
7 0~345-2068 KPa
8 0~1170-6890 KPa
9 0~3450-20680 KPa
0 0~6890-41370 KPa
output E 4-20mADC
F Intelligent Hart protocol
J 4-20mADC is the square root of input pressure
Material of liquid receiving parts Flange joint Exhaust/exhaust valve Isolation Diaphragm Fill with liquid
22 316 stainless steel 316 stainless steel 316 stainless steel silicone oil
23 316 stainless steel 316 stainless steel Hastelloy C silicone oil
24 316 stainless steel 316 stainless steel Monel silicone oil
25 316 stainless steel 316 stainless steel tantalum silicone oil
33 Hastelloy C Hastelloy C Hastelloy C silicone oil
35 Hastelloy C Hastelloy C tantalum silicone oil
44 Monel Monel Monel silicone oil
additional function M1 0-100% linear indicator table
M2 0-100% Square Root Indicator
M3 31/2 LCD digital display
Without header
B1 Pipe bending installation plate
B2 Plate bending installation plate
B3 Pipe installation safety installation board
Without installation board
D1 The discharge valve is located at the upper part of the pressure chamber
D2 The drain valve is located at the lower part of the pressure chamber
C1 1/2-14NPT pressure joint rear welded with a Ø 14 pressure pipe
C2 M20 × 1.5 T-shaped male threaded connector
C3 M20 × 1.5 T-shaped male threaded connection block with additional T-shaped joint
C4 1/2-14NPT taper pipe female thread connector
d Explosion proof Exd Ⅱ BT4
i Intrinsic safety type ia Ⅱ CT6
Static pressure 1MPa
Static pressure 4MPa
H1 Static pressure 10MPa
H2 Static pressure 14MPa
H3 Static pressure 25MPa
H4 Static pressure 32MPa