Infrared Imaging and Temperature Measurement System for Glass Kiln Furnaces PYRONINC 380G
In May 2014, the kernel was changed to PYROVIEW 640G Protection,
The new model is PYRONINC 640G
feature
• Temperature measurement range: 600 ° C~1250 ° C; optional up to 2500 ° C
• Measurement frequency: 50Hz
• Non cooled miniature thermal radiometer, 384 × 288 pixels (new model pixel 640 * 480)
Kiln probe with air blower and water cooling system for combustion chamber
• There are different probe lengths and different field of view angles, with optional tilt angles for the field of view
Durable casing (IP65) with optional water cooling system
Real time data acquisition through optical fiber
• Can trigger measurement, alarm monitoring, and threshold monitoring
• Greater dynamic range and 16 bit A/D conversion increase accuracy
• Customizable system solutions: with automatic telescopic and rotating devices, control cabinets for monitoring cooling media or blowing air, and customized software for customers.
application
The PYRONINC 640G online infrared thermal imager provides non-contact temperature measurement for glass kilns.
Typical applications of thermal imagers include optimizing the thermal process of glass kilns and detecting deposits.
software
PYROLOFT software is suitable for Windows ® There are browsing version Viewer, Compact version, Professional version Professional, DAQ version suitable for user development environment, Basic version Basic, and Control version suitable for participating in control; This series of software has powerful functions, allowing users to record, store, and browse measurement data and thermal images, as well as manipulate and control thermal imagers. The main features are as follows:
Real time data recording
Partition definition, alarm monitoring, threshold monitoring
Trend analysis
• Data output (text, bitmap, video format)
Process control is achieved through PROFIBUS bus, analog and digital input/output, and other types of interfaces.
Users can use the programming interface (Windows) ®- DLL programming is used for user system integration.

Technical data
model |
PYROINC640M |
PYROINC640F |
PYROINC640C |
PYROINC640G |
|
spectral range (Other customized according to requirements) |
MWIR |
Equipped with flame filter |
CO2 |
glass |
3~5 µm |
3.9 ± 0.1 µm |
4.55 ± 0.05 µm |
4.8~5.2 µm |
|
detector |
Two dimensional uncooled infrared thermal radiometer |
|||
pixel |
640 x 480 |
640 x 480 |
640 x 480 |
640 x 480 |
Frame rate (adjustable) |
≤ 50 Hz |
≤ 50 Hz |
≤ 50 Hz |
≤ 50 Hz |
|
Measuring range (Other ranges can be customized) |
300-1,000°C |
600-1,250°C |
600-1,250°C |
600-1,250°C |
(Optional up to 1800 ° C) |
(Optional up to 1800 ° C) |
(Optional up to 1800 ° C) |
||
Temperature Resolution (NETD) |
1K |
|||
(f=1Hz/T target=1000 ° C) | ||||
Optical coefficient |
28 ° * 21 °/ø 70mm-200 mm 61 ° * 48 °/60 ° left oblique view/ø 104mm * 1055mm |
|||
(FOW)/ |
43°* 33°/ø70mm-200mm 61°*48°/ 60° 斜视/ ø104mm*1055mm |
|||
|
Probe diameter (Other customized according to requirements) |
67°x52°/ø90mm-500mm 45°x 45°/ø104 mm*1055 mm |
|||
measurement error |
2% measurement value (T target temperature) |
|||
focusing |
1 m~infinity |
|||
file format |
16 digit number |
|||
interface |
Fiber optic interface, 50 Hz data transmission or Fast Ethernet (standard) |
|||
Shell/Size/Weight |
IP65 (NEMA 4) aluminum cast casing/196 mm x 266 mm x 100 mm/approximately 3.2 kg |
|||
joint |
Spiral connector (16 pins) for power supply, - fiber optic plug-in type (2 pins) |
|||
2 x water (width 4 mm, maximum pressure 2 bar) | ||||
1 x pressurized air (4 mm wide, maximum pressure 2 bar) | ||||
Digital I/O channel |
Up to 4 channels (LED input (5 V ≤ UE ≤ 25 V) and optocoupler output (IC ≤ 50 mA, UE ≤ 25 V)) |
|||
power input |
18~36 V DC, 10~20 VA |
|||
Operating temperature (thermal imager) |
-25 to+150 ° C (standard, optional with integrated water cooling system) |
|||
Operating temperature (probe) |
+2000°C |
|||
Storage temperature |
-20~+70 ° C, maximum relative humidity 95% |
|||
software |
1. PYROSOFT Basic (free) is used for data collection, storage, visualization, and data output |
|||
*. BMP, *. XLT and *. TXT (ASCII) files. (Windows ® XP) | ||||
2. PYROSOFT Analyzer (optional) is used for data collection, storage, visualization, professional data analysis, and formation | ||||
*. HTML and * DOC report, data output format * BMP, *. JPG, *. EMF, *. AVI, *. CSV, and * TXT (ASCII) file | ||||
3. PYROSOFT Control (optional) is used for data acquisition, storage, visualization, industrial data analysis, and I/O channels | ||||
And data output format * BMP, *. XLT, and * TXT (ASCII) file | ||||
4. PYROSOFT INC Control (optional) is used for data acquisition, professional data analysis, I/O channels, and data input | ||||
Output format * BMP, *.XLT, *.TXT (ASCII)。 | ||||
5. Customizable software can be used to control the ignition zone of the garbage incinerator. | ||||