Dongguan Ouruosi Instrument Co., Ltd
Home>Products>Pannuo Instrument Tetravalent Benzene Detector
Pannuo Instrument Tetravalent Benzene Detector
How much does the Panno instrument RoHS 2.0 ten item detection instrument cost, and how much does the Panno instrument RoHS 2.0 ten item detection ins
Product details

EU RoHS adds four basic restricted substances, which will become RoHS ten
On June 4, 2015, the Official Journal of the European Union (OJ) issued the revised RoHS2.0 directive (EU) 2015/863, and the update to EU RoHS2.0 was finally settled. The original six controlled substances, lead (Pb), mercury (Hg), cadmium (Cd), hexavalent chromium (Cr VI), polybrominated biphenyls (PBB), and polybrominated diphenyl ethers (PBDE), were changed to ten controlled substances, and di (2-ethylhexyl) phthalate (DEHP), toluene butyl phthalate (BBP), dibutyl phthalate (DBP), and diisobutyl phthalate (DIBP) (abbreviated as 4P4P4P), were added. HBCCD, which was previously prioritized as an evaluated substance in ROHS 2.0, has not been officially included in the list of restricted substances. The limit for the control of these ten controlled substances is 0.1%.
After the issuance of this revised directive, EU member states are required to translate it into their own regulations and implement it by December 31, 2016. Starting from July 22, 2019, all electronic and electrical products exported to Europe (excluding medical and monitoring equipment) must meet this restriction requirement, which means that companies still have four years to respond to the ROHS change; Starting from July 22, 2021, medical equipment (including extracorporeal medical equipment) and monitoring equipment (including industrial monitoring equipment) will also be included in this control scope. In addition, toy products that are already subject to benzene control under Article 51 of Annex XVII of REACH will not be subject to the control of DEHP, BBP, and DBP under this directive.

Mainly used for testing organic compounds,Such as phthalates, polycyclic aromatic hydrocarbons, organotin, dimethyl fumarate、 N. Testing of organic compounds such as N-dimethylformamide, azo dyes, short chain chlorinated paraffins, N-methylpyrrolidone, chlorinated phenols, alkylphenols, pesticide residues, melamine, volatile organic compounds, semi volatile organic compounds, etc.

AMD5 is a carefully crafted high cost-effective gas chromatography-mass spectrometry analyzer, equipped with a GC-MS workstation: full Chinese interface, self built spectrum library NIST 2014 optional, fully modular design. Widely used in many fields such as petrochemicals, food safety, environmental protection, etc.

Pannuo Instrument Tetravalent Benzene Detector

Common solutions:

64 types of VOC testing for water quality

49 types of pesticide residues in traditional Chinese medicine

16 types of polycyclic aromatic hydrocarbons

ROHS testing -10 types of polychlorinated biphenyls

7 types of phthalates

Technical parameters:

1. Chromatographic indicators:

Type of injection port: capillary column with EPC diversion, maximum diversion ratio 1000:1

How much is the price of the ten testing instruments for Panno RoHS 2.0

Column box, heating step, temperature stability:

Temperature: 4 ℃ -450 ℃ above room temperature, set value resolution: 1 ℃, column temperature change<0.01 ℃ for every 1 ℃ change in room temperature.

Heating rate limit: 120 ℃/min

Running time limit: 999.99min

Cooling rate: 450 ℃ -50 ℃,<4 minutes. 20 steps, 21 platforms, with gradient cooling capability

Electronic pneumatic control:

Pressure setting range: 0-150psi

Control accuracy: 0.001psi within the range of 0.000 to 99.999psi

Within the range of 100.00 to 150.00 psi, it is 0.01 psi

Flow setting range: 0-200ml/min (N2)

0-1000ml/min(He)

Multiple electronic flow control channels are used for injection ports, detectors, or auxiliary gases to adjust pressure in increments of 0.1 psi (accuracy)

Atmospheric pressure sensor compensates for changes in altitude or environment

Program boost/boost current: 3rd order

Multiple control modes: constant current, constant voltage, program boost, program boost, pulse pressure

Heating zone: Excluding column box, there are 6 independent heating zones: 2 injection ports, 2 detectors, and 2 auxiliary heating zones each. The temperature limit for the auxiliary heating zone is 400 ℃.

2. Simplicity index:

Temperament interface: Simple and independent temperature control, does not occupy chromatographic resources, temperature limit: 350 ℃.

Filament: Dual filament.

Ionization energy: adjustable from 10eV to 100eV

Ion source temperature: accurate temperature control ± 0.1 ℃, limit value 350 ℃.

Quality analyzer: Surface passivation, gold-plated high-precision four stage rod, pre four stage and main four stage rod integrated assembly.

Front stage vacuum pump: mechanical pump, pumping speed 3m3/h

Rear stage vacuum pump: Turbomolecular pump, with optional pumping speeds of 71L/S and 260L/S.

Detector: Electron multiplier.

Control method: Network port control.

RF power supply: dual frequency modes of 1.0MHz and 1.4MHz.

Quality range: 1.5u to 1050u

Quality accuracy: ± 0.1u

Quality stability: ± 0.1u, 48 hours

Resolution: resolution per unit mass.

Signal to noise ratio: 1pg OFN full scan>200:1 RMS

Select ion 0.1pg OFN 272 ≥ 200:1 RMS

Scanning speed limit: 11000u/s

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!