Standard test refers to SC-F2B
●product overview
Compliant with IEC61032 Figure 2 Test Tool B, GB2099, GB4208IP2, GB4706, GB4943, GB3883 Figure 1, GB/T16842, IEC60950 Figure 2A, IEC60884, IEC60335, UL507, EN60529 Figure 1, and UL1278 Figure 8.4 standards, used for protective testing against finger contact or electric shock.
The standard test refers to a finger that simulates a human finger, consisting of a finger, finger center, finger holder, and insulated handle. There are two active joints that can bend within 90 degrees. Can: The end of the handle is equipped with a pluggable banana plug and wiring terminal for anti electric shock testing, or the end of the handle is opened with an M6 threaded hole (used in conjunction with a push-pull force gauge) for shell protection testing.

●Main specifications and corresponding technical parameters:
Parameters/Model |
SC-F2B |
SC-F2B-F |
name |
Standard Test Finger |
Thrust standard test refers to |
1 |
30±0.2 |
30±0.2 |
2 |
60±0.2 |
60±0.2 |
3 |
80±0.2 |
80±0.2 |
4 |
180±0.2 |
180±0.2 |
5 |
R2±0.05 |
R2±0.05 |
6 |
S4±0.05 |
S4±0.05 |
7 |
37o 0 -10’ |
37o 0 -10’ |
8 |
14 o 0 -10’ |
14 o 0 -10’ |
9 |
Ф12 0 -0.05 |
Ф12 0 -0.05 |
10 |
Ф50 |
Ф50 |
11 |
20±0.2 |
20±0.2 |
12 |
Ф75±0.2 |
Ф75±0.2 |
13 |
5±0.5 |
5±0.5 |
14 |
---- |
10-50N thrust |