overview
■Scope of application:
The self resetting overvoltage and undervoltage protector is suitable for users or loads with single-phase AC voltage of 220V, frequency of 50Hz, and rated working current of 60A and below. As a protection for single-phase electrical equipment against overvoltage and undervoltage caused by neutral line faults. Mainly used for the protection of residential sub boxes or distribution lines that require protection of single-phase electrical equipment.
■Features and advantages:





■ Application
-Overvoltage and undervoltage protection for household appliances.
■ Functional Features
-Power supply voltage measurement protection (true RMS voltage measurement).
-The dual manifold design has stronger wiring capability.
-It can achieve self starting and self resetting functions.
-Voltage measurement accuracy ≤ 1%.
-The three-phase model has the functions of disconnection and phase sequence detection.
-The fault status can be displayed through LED.
-Installed on a 35mm standard guide rail.
Model and meaning

Main technical parameters
| 2P | 4P | |
| rated supply voltage | AC220V | AC220V(L-N) |
| Rated power frequency | 50/60Hz | |
| Rated current | 32A, 40A, 63A (resistive) | 63A (resistive) |
| Overvoltage action value | 265V | 265V(L-N) |
| Overvoltage reset value | 257V | 257V(L-N) |
| Undervoltage action value | 175V | 175V(L-N) |
| Undervoltage reset value | 180V | 180V(L-N) |
| Action delay time | 1s (overvoltage, undervoltage), 0.1s (phase failure, phase sequence) | |
| Power on delay time | 2s | |
| Reset delay time | 30s | |
| Voltage measurement error | ≤1% | |
| Delay error | ±10%+0.1s | |
| rated insulation voltage | 250V | |
| IP GRADE | IP20 | |
| pollution degree | 3 | |
| Electrical life | 105 | |
| mechanical life | 106 | |
| altitude | ≤2000m | |
| Ambient Temperature | -5℃~40℃ | |
| Allowable relative humidity | ≤ 50% (40 ℃) (no condensation) | |
| storage temperature | -25℃~55℃ | |
| Guide rail standard | Width 35mm (IEC/EN60715) | |
Wiring diagram

function diagram

Appearance and installation dimensions

Application examples