Product Features
Customer Case
Integrated refrigeration of low-temperature chiller units by China Salt Group
Yanzhong Beverage Process Cooling Integrated System
Cube Pharmaceutical Integrated Industrial Refrigeration
Advantages of Stellar Seasons
20 Technology Sedimentation Casting Fine Star Seasons
20 years of production and manufacturing experience, 3 major production bases, 50000 square meters of production plants, fully automated production lines, national calibration and testing system, 108 production processes with strict quality control management to ensure that the quality of each product meets national quality standards
40 patented technologies save 30% energy
Jointly established a refrigeration system project design and research institute with the University of Science and Technology of China, with 4000 industry solution experiences, over 40 patented technologies, and energy savings of over 30% in operation
Professional technical team provides free solution design
A technical team of 20 people provides free targeted overall solutions for different enterprise project situations. According to enterprise needs, customized and reliable systems can be provided to safeguard enterprise production
Double after-sales service guarantee solves worries
7 × 24-hour after-sales service team, IoT mobile APP remote monitoring system, providing fault warning function to reduce the impact of equipment failure, lifetime warranty, and helping enterprise development
| Technical parameters of sewage source heat pump unit | |||||||||
| type number 20STB-Model | 20WHDC4 | 25WHDC4 | 30WHDC4 | 40WHDC4 | |||||
| refrigerant | R22 | ||||||||
| Nominal heating capacity |
×1000 kcAHl/h | 64.7 | 78.5 | 100.6 | 135.5 | ||||
| kW | 75.2 | 91.3 | 117.0 | 157.5 | |||||
| Compressor input power |
kW | 15 | 17.1 | 23.1 | 31 | ||||
| Cold recycling capacity |
kW | 60.2 | 74.2 | 93.9 | 126.5 | ||||
| electricity source Power supply | 3φ-380V-50Hz | ||||||||
| protective device Protection device |
Reverse phase protection, phase loss protection, overcurrent protection, exhaust temperature protection, high and low voltage protection, low temperature protection, reserved water flow protection interface Phase Peversion Protection、Phase Lack Protection、Overload Current Protection、The Reserved Water Protection Interface |
||||||||
| 制冷回路 | 2 | ||||||||
| Energy control% Capacity control | 0,50,100 | ||||||||
| Refrigerant Charge | 3*2 | 3.5*2 | 4*2 | 5*2 | |||||
| hot water | Maximum pressure on the water side | 1 | |||||||
| inlet and outlet pipe diameter | 2″ | 2-1/2″ | |||||||
| Hot water flow rate | 4.3 | 5.2 | 6.7 | 9.0 | |||||
| Water pressure drop | 27 | 40 | 50 | 45 | |||||
| sewage | Maximum pressure on the water side | 1 | |||||||
| inlet and outlet pipe diameter | 2″ | 2-1/2″ | |||||||
| Sewage flow rate | 5.2 | 6.4 | 8.1 | 10.9 | |||||
| Water pressure drop | 27 | 40 | 50 | 45 | |||||
| Running noise Running noise dB(AH) | 65 | 65 | 70 | 65 | |||||
| Total weight Total Weight(kg) | 900 | 1000 | 1200 | 1350 | |||||
| Runnig weight (kg) | 1000 | 1100 | 1300 | 1480 | |||||
-
Note:
1. Nominal heating conditions: sewage inlet and outlet temperatures of 15 ℃/5 ℃, hot water inlet and outlet temperatures of 30 ℃/45 ℃;
2. Sewage temperature range: 5 ℃~20 ℃;
3. The maximum outlet temperature of hot water is 55 ℃;
4. Cold recovery and heat recovery are optional parameters. When selecting the heat recovery function, the amount of heat recovered is the same as the input power of the compressor.