spectrometryCODmeasuring instrumentCarboVis700IQ
feature
on-line measurementCODTheBODTheTOCTheTSSAnd nitrate nitrogen, nitrite nitrogen
Bricklay optical system ensures high precision, stability, and reliability
Full spectrum ensures * good results and compensation
Advanced ultrasonic cleaning system ensures minimal maintenance
Titanium alloy andPEEKMaterial, more resistant to chemical corrosion
Standard plastic cushioning protective cap, impact resistant, super durable
Measuring principle
The basic working principle is UV visible continuous spectral scanning. When a beam of light passes through the test liquid, any substance in the liquid will absorb the light, reducing the intensity of the transmitted light. The instrument measures the absorbance at different wavelengths to depict the absorption curve. By analyzing the absorption curve, the test component can be qualitatively and quantitatively tested. At the same time, solid particles in the liquid will scatter light in various directions, causing a decrease in the intensity of transmitted light (at all wavelengths). Continuous spectral scanning can effectively compensate for the influence of changes in the background composition of the tested liquid. The probe tested using this method has a certain testing interval and cannot be tested continuously.
Germany WTWThe spectral COD measuring instrument adopts a new optical design, with a symmetrical measurement system and reference system, the same optical elements, light intensity, light quantity, and optical path length, so it has automatic drift compensation and does not require conventional zeroing.
Spectral COD measuring instrumentCarboVis 700IQThe flicker frequency of the light source can be automatically adjusted according to different samples to ensure that the light signal is neither too strong nor too weak, with a very low signal-to-noise ratio and reliable measurement data.
automatic cleaning
Spectral COD measuring instrumentCarboVis 700IQThere are multiple cleaning methods available, with the option to choose between ultrasonic cleaning or compressed air cleaning separately, as well as a combination mode of ultrasonic cleaning+Compressed air cleaning.
Ultrasonic cleaning system
Spectral COD measuring instrumentCarboVis 700IQThe probe is equipped with an ultrasonic cleaning system as standard, which ensures long-term reliable operation and saves maintenance. Optical lenses will vibrate slightly under the action of ultrasound, which can effectively prevent pollutants from adhering to the optical lenses, greatly improving the stability and reliability of testing.
Air blowing device (optional)
When the on-site conditions are extremely harsh, it is recommended that users choose another set of high-pressure air blowing device to achieve dual safety and ensure the reliable operation of the system.
Other spectral sensors are optional
- NitraVis®Measurement of nitrate and nitrogen parameters
-- nitravis ® NiMeasurement of nitrate nitrogenNitrous nitrogen parameters
- NiCaVis®: MeasurementCOD、Nitrate nitrogen
-- nicavis ® Ni: MeasurementCOD、Nitrate nitrogen、nitrite
Technical Specifications
|
model |
Nitravis 705 IQ (by / TS) |
Nitravis 701 IQ (by / TS) |
CarboVis |
CarboVis |
NiCaVis |
NiCaVis |
NiCaVis |
|
Measuring principle |
UV-VIScontinuous spectrum200-720nm |
UVcontinuous spectrum200-390nm |
|||||
|
application |
discharge outlet |
Entrance, aeration tank |
discharge outlet |
Entrance, aeration tank, and discharge outlet |
discharge outlet |
Entrance, aeration tank, and discharge outlet |
discharge outlet |
|
measurement range [mg/l] |
NO3-N:
NIIncrease measurement NO2-N: 0.00 . .. 75.00 |
NO3-N:
NIIncrease measurement
NO2-N: |
COD:
BOD:
TOC:
SAC: |
COD:
BOD:
TOC:
SAC: |
COD:
BOD:
TOC:
SAC:
NO3-N: |
NO3-N: 0…150.00 NO2-N: 0… 75.00 COD: 0…20000.0 |
NO3-N: 0…50.00 NO2-N: 0…25.00 COD: 0 … 800.0 |
|
TSS |
Entrance, aeration tank: |
discharge outlet: |
entrance:
discharge outlet: |
entrance:
discharge outlet: |
|
|
|