Tai Gui testing hardness steel plug socket gauge
Thai standard instrument hardness steel plug socket gauge GB1003, GB1002 Thai standard instrument plug socket gauge, national standard gauge.
Product details

1、 The plug and socket gaugePurpose:
Used for measuring and verifying the dimensions of plugs and sockets for household and similar purposes.
IIOverview:
Compliant with the requirements of GB1002-2008 and GB2099.1-2008 standards;
Material: S136 mirror steel;
Hardness: 58-62HRC;
The geometric tolerances such as parallelism, perpendicularity, and symmetry comply with the tolerance level H specified in GB/T1184-1996;
IIIProduct Name, Specification, Quantity: A total of 19 pieces
Single phase two pole plug gauge 6A, 10A 1 piece
Two single-phase two pole grounded plug gauges, one for 6A and one for 10A and 16A respectively, for a total of two pieces
Single phase two pole grounding plug external gauges 10A and 16A, 1 piece each, a total of 2 pieces
Single phase two pole socket with the largest standard 10A1 piece
Single phase two pole socket with 10A1 small pass gauge
Single phase two pole socket with 10A1 small stop gauge
Single phase two pole socket with no contact gauge 10A1 piece
Two single-phase two pole grounded sockets, one large gauge 10A and one 16A, totaling two pieces
Two single-phase two pole grounded sockets, one 10A and one 16A respectively, with a total of two pieces
Two single-phase two pole grounded sockets, one 10A and one 16A respectively, for a total of two pieces
Single phase two pole grounded socket with no contact specification 10A, 16A, 1 piece each, a total of 2 pieces
Single phase two pole dual socket round plug part with 10A1 pass gauge
Single phase two pole dual socket round plug part with 10A1 stop gauge

serial number

Project Name

drawing number

quantity

unit

GB1003-2016(GB2099.1 Chapter 9.1)

1

Three phase five wire plug gauge

Figure 5 (16A)

1

document

2

Three phase five wire plug gauge

Figure 5 (25A)

1

document

3

Three phase five wire plug gauge

Figure 5 (32A)

1

document

4

Three phase four wire socket standard

Figure 6 (16A)

1

document

5

Three phase four wire socket standard

Figure 6 (25A)

1

document

6

Three phase four wire socket standard

Figure 6 (32A)

1

document

7

Three phase five wire socket standard

Figure 6 (16A)

1

document

8

Three phase five wire socket standard

Figure 6 (25A)

1

document

9

Three phase five wire socket standard

Figure 6 (32A)

1

document

10

Three phase four wire socket stop gauge

Figure 7 (16A)

1

document

11

Three phase four wire socket stop gauge

Figure 7 (25A)

1

document

12

Three phase four wire socket stop gauge

Figure 7 (32A)

1

document

13

Three phase five wire socket stop specification

Figure 7 (16A)

1

document

14

Three phase five wire socket stop specification

Figure 7 (25A)

1

document

15

Three phase five wire socket stop specification

Figure 7 (32A)

1

document

16

Three phase four wire socket non-contact specification

Figure 8 (16A)

1

document

17

Three phase four wire socket non-contact specification

Figure 8 (25A)

1

document

18

Three phase four wire socket non-contact specification

Figure 8 (32A)

1

document

19

Three phase five wire socket non-contact specification

Figure 8 (16A)

1

document

20

Three phase five wire socket non-contact specification

Figure 8 (25A)

1

document

21

Three phase five wire socket non-contact specification

Figure 8 (32A)

1

document

22

Three phase five wire socket non-contact specification

Figure 9 (16A)

1

document

23

Three phase five wire socket non-contact specification

Figure 9 (25A)

1

document

24

Three phase five wire socket non-contact specification

Figure 9 (32A)

1

document

GB1002-2008(GB2099.1 Chapter 9.1)

1

Single-phase two pole plug gauge

Figure 6

1

document

2

Single phase two pole grounded plug internal gauge

Figure 7 (10A)

1

document

3

Single phase two pole grounded plug internal gauge

Figure 7 (16A)

1

document

4

Single phase bipolar grounding plug external gauge

Figure 8 (10A)

1

document

5

Single phase bipolar grounding plug external gauge

Figure 8 (16A)

1

document

6

Single phase two pole socket * large gauge

Figure 9 (10A)

1

document

7

Single phase two pole socket * small pass gauge

Figure 10

1

document

8

Single phase two pole socket stop gauge

Figure 11

1

document

9

Single phase two pole socket non-contact specification

Figure 12

1

document

10

Single phase two pole grounded socket * large gauge

Figure 13

1

document

11

Single phase two pole grounded socket * large gauge

Figure 13

1

document

12

Single phase two pole grounded socket * small pass gauge

Figure 14

1

document

13

Single phase two pole grounded socket * small pass gauge

Figure 14

1

document

14

Single phase two pole grounded socket stop gauge

Figure 15 (10A)

1

document

15

Single phase two pole grounded socket stop gauge

Figure 15 (16A)

1

document

16

Single phase two pole grounded socket non-contact specification

Figure 16 (10A)

1

document

17

Single phase two pole grounded socket non-contact specification

Figure 16 (16A)

1

document

18

Single phase two pole dual use plug circular pin partial pass gauge

Figure 17

1

document

19

Single phase two pole dual use plug circular pin partial stop gauge

Figure 18

1

document

GB1002Pull out plug gauge (GB2099.1 Chapter 22)

20

*Large pulling force

6A,10A,16A

3

document

21

Single sales * small pull-out plug

10A,16A

3

document

GB1002Lateral stress plug gauge (GB2099.1 Chapters 13 and 14)

22

Lateral stress plug gauge

6A,10A,16A

3

document

GB1002Temperature rise plug gauge (GB2099.1 Chapter 19)

23

Temperature rise plug gauge

6A,10A,16A

3

document

GB1002Normal operation, segmented capacity gauge (GB2099.1 Chapters 20 and 21)

24

Normal operation, segmented capacity gauge

6A,10A,16A

3

document

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!