Technical Standards and Requirements for Equipment of Botuo Instrument Water Quality Automatic Monitoring Station Building Monitoring Station System JCZG-209G
Technical standards and requirements for water quality automatic monitoring station building monitoring station system equipment in accordance with th
Product details

Technical standards and requirements for equipment of water quality automatic monitoring station building monitoring station system
Technical standards and requirements for equipment of water quality automatic monitoring station building monitoring station system
Technical standards and requirements for equipment of water quality automatic monitoring station building monitoring station system

According to the Technical Specification for Automatic Detection of Surface Water(Trial) "(HJ915-2017) and" Spectral Water Quality Online Monitoring System "(T/CWEC 13-2019)Requirements for the construction and operation management of monitoring systems in China. The instruments and detection principles of water stations should be determined based on the characteristics of water pollution factors, instrument applicability, comparability of monitoring results, and water function. According to the Technical Specification for Automatic Detection of Surface Water(Trial) "(HJ915-2017) Appendix A Instrument Performance Requirements and" Spectral Water Quality Online Rapid Monitoring System "(T/CWEC 13-2019) and other new practical testing methods. Currently, the monitoring methods involved in this project are shown in the table below2As shown:
table2. Requirements for Analysis Methods
ordernumber project method Remarks
1 ammonia nitrogen Nessler's reagent spectrophotometry, salicylic acid spectrophotometry, electrode method HJ915-2017
HJ/T 101-2003
2 Permanganate index Potassium permanganate oxidation method (HJ/T100-2003) HJ915-2017 adoption method
absorbspectrumlaw T/CWEC13-2019 standard
3 Total Phosphorus Ammonium molybdate spectrophotometric method (HJ/T103-2003) HJ915-2017 adoption method
4 traffic Radar method Flow rate: GB/T15966-2007 Water level: GB/T27993-2011
Fixed-point acoustic Doppler method SL 337-2006