English

Shanghai Botuo Instrument Co., Ltd
Home>Products>The high COD content of BOQU instrument poses a threat to human health. BOQU COD online analyzer CODG-3000
The high COD content of BOQU instrument poses a threat to human health. BOQU COD online analyzer CODG-3000
The high COD content of BOQU instrument poses a threat to human health. BOQU COD online analyzer CODG-3000
Product details
BOQU COD online analyzer - COD analyzer for wastewater quality CODG-3000
BOQU COD online analyzer - COD analyzer for wastewater quality CODG-3000
BOQU COD online analyzer - COD analyzer for wastewater quality CODG-3000

CODG-3000typeCODChromium method online automatic analyzer
The CODG-3000 COD fully automatic online analyzer is a COD automatic monitoring instrument with completely independent intellectual property rights, which can automatically monitor COD in various water bodies for a long time without human supervision.

Technical Indicators:
Method basis: National standardsGB11914-89 "Water Quality - Determination of Chemical Oxygen Demand - Potassium Dichromate"
Measurement range:5-5000 mg/L COD
accurate indeed Degree:When ≥ 100mg/L, not exceeding ± 10%; When<100mg/L, not exceeding ± 8mg/L
heavy again Sex:When ≥ 100mg/L, not exceeding ± 10%; When<100mg/L, not exceeding ± 6mg/L
Indication error: not exceeding±10%
Measurement cycle: *The small measurement cycle is50 minutes, according to the actual water sample, the digestion time can be modified arbitrarily within 5-120 minutes
Sampling period: Time interval(55~9999min adjustable) and whole point measurement mode
Calibration cycle:Adjustable at any interval and time from 1 to 99 days
Maintenance cycle: Usually once a month, about30min
lose Out:4~20mA(2路) RS232、RS485
relay output: 2 control relay outputs
Environmental requirements: Indoor temperature adjustable, recommended temperature+5~28℃; Humidity ≤ 90% (non condensing)
electricity Source:AC220±10% V,50±10% Hz,5 A
ruler Inch: Height1570 x width 500 x depth 450 mm
its He:Abnormal alarms and power outages will not result in data loss; Touch screen display and command input; After abnormal reset and power failure, the instrument will automatically discharge residual reactants and restore working status.
Domestic COD online monitoring instrument, sewage discharge outlet testing instrument, domestic online ammonia nitrogen detection, salicylic acid ammonia nitrogen testing instrument, high COD content, harm to human body, domestic COD online monitoring instrument * List
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!