The YC9100-4Z touch sensitive COD ammonia nitrogen total phosphorus total nitrogen turbidity suspended solids heavy metal analyzer is designed and developed based on relevant national standards. It adopts a 7-inch resistive touch screen, flat icon design, guided operating system, and simple and easy to understand interface, allowing operators to use it quickly and accurately.The operation does not require manual intervention, and the system automatically identifies the detection channel for precise detection. The detection uses a 16mm digestion detection integrated optical colorimetric tube, simplifying the operation steps and avoiding errors caused by repeated liquid removal, greatly improving accuracy.
Technical Parameter
|
Testing items |
COD |
Ammonia nitrogen |
total phosphorus |
total nitrogen |
turbidity |
Suspended solids |
||
|
Testing standards |
HJ/T399-2007 |
HJ535-2009 |
GB1183-89 |
EPAColor changing acid method |
Determination of turbidity in water quality |
Improvement of National Standard Weight Method |
||
|
Range of measurement |
0-15000mg/L |
0-50mg/L |
0-20mg/L |
0-100 mg/L |
0-1000NTU |
0-500mg/L |
||
|
limit of detection |
5mg/L |
0.01mg/L |
0.02mg/L |
0.5mg/L |
0.5mg/L |
5mg/L |
||
|
Dissolve the environment |
165℃,20min |
No need to dissolve |
125℃,30min |
125℃,30min |
No need to dissolve |
No need to dissolve |
||
|
Testing items |
total chromium |
hexavalent chromium |
copper |
zinc |
nickel |
iron |
||
|
Testing standards |
GB7466-87 |
GB7467-87 |
bco |
Xylenol orange method |
GB11910-89 |
HJ/T345-2007 |
||
|
Range of measurement |
0-5mg/L |
0-5mg/L |
0-50mg/L |
0-15mg/L |
0-4mg/L |
0-50mg/L |
||
|
limit of detection |
0.001 |
0.001 |
0.01 |
0.02 |
0.009 |
0.004 |
||
|
Measurement Error |
≤± 5% |
repeatability |
≤±3% |
|||||
|
Optical stability |
≤±0.001A/20Minutes(100000Hour without decay) |
Colorimetric method |
Colorimetric tube (digestion colorimetric integrated tube) |
|||||
|
transmission mode |
USBLocal Area Network |
Printing method |
Built in thermal printer |
|||||
|
display |
7Inch color touch screen |
Operation interface |
Touchscreen Chinese/English (optional) |
|||||
|
Power supply mode |
AC(220V±10%),50Hz |
Storage |
3Ten thousand records96Curve (supports customization) |
|||||
|
power |
5W |
work environment |
5-45℃ ≤85%No condensation |
|||||
|
Host size |
348mm*250mm*145mm |
|||||||
|
Instrument weight |
host<2.6kg; Dissolver<7kg |
|||||||
Technical parameters of digestion instrument
|
Dissolve sample size |
25branch |
time display |
Real time date and time display |
|
Operation interface |
Chinese display |
operating mode |
Touch-tone |
|
rated voltage |
AC 220V±10%/50Hz |
Power requirements |
grounding |
|
Dissolve pore size/depth |
16mm/65mm |
Dissolving capacity |
>12mL |
|
display screen |
TFTHigh definition color screen |
timing error |
10min±0.1s |
|
Pre set digestion mode |
CODTotal phosphorus, total nitrogen |
Dissolution method |
Fully enclosed type |
|
safety protection |
Double protection against overheating |
temperature control |
intelligencePIDtemperature control |
|
custom mode |
5The temperature and time can be set arbitrarily |
Project switching |
Quick switch |
|
Reminder method |
buzzer |
Alarm prompt1 |
Reaching the specified temperature and maintaining a constant temperature |
|
Custom time |
5-999minadjustable |
Alarm prompt2 |
Dissolve completed and stop heating |
|
Custom Temperature |
90~200℃ adjustable |
Dissolve protection |
Heat shield/shield |
|
Temp Accuracy |
<±0.5℃ |
Temperature control sensor |
Imported PlatinumPT100 |
|
heating rate |
Set to165℃,12Constant within minutes |
Instrument weight |
6kg |
|
work environment |
-10-40℃, relative humidity<85% |
External dimensions |
230*340*130(mm) |
Example of operating interface
Instrument characteristics
1. Full touch design: 7-inch touch screen, supporting Chinese/English display (optional), guided operating system, simple and time-saving.
2. Wide detection range: dozens of detection parameters can be expanded, and customized according to customer needs.
3. Detection optics: Adopting independent multi module optical (imported) design, excellent optical performance, stable and reliable.
4. Operating System: Guided operating system with a simple and easy to understand interface, guiding users to complete operations quickly and accurately.
5. Operating program: a. Built in system program and user program, which can add frequently tested items to the user program for easy searching.
b. It has power-off protection function and one click factory reset function to prevent data loss.
c. The built-in standard work program can be used directly, and users can also expand the detection items themselves.
d. Built in help interface, which can query user detection process problems and issues.
e. It has a one click factory reset function, which can quickly recover data loss in case of unexpected situations.
6. Intelligent detection: Standard measurement and continuous measurement can be switched freely, reducing repeated measurement steps and improving detection efficiency.
7. Operation safety: Adopting a digestion colorimetric integrated tube, reducing the steps of transferring reagents, making the measurement simple, fast, and safe.
8. Quick printing: Equipped with a built-in thermal printer, it can print both current and historical measurement data.
9. Data storage: Standard working curve and 96 user-defined items, capable of storing 30000 pieces of detection data.
10. Online function: Supports data transfer between network port, LAN, USB and PC or printer.
11. Professional reagents: specialized reagents, simplified operating procedures, reduced operational errors, less reagent usage, and lower consumable prices.