◆ Meet the requirements of "DL/T848.4-2004 General Technical Conditions for High Voltage Test Equipment Part 4: Triple Frequency Test Transformer Device", use the saturation characteristics of the magnetic circuit to extract the third harmonic voltage with the largest component in the harmonic, and use it as the power supply for the generator to conduct double frequency and double voltage tests on induction coil type electrical products between turns, segments, and layers; To assess the insulation strength and withstand voltage level of the coil.
The YHSBP series triple frequency induction withstand voltage test device is used for longitudinal insulation induction testing of interlayer, turn to turn, section to phase insulation of transformers and transformer windings. It is an important project to test whether the windings meet the requirements.
The triple frequency induction withstand voltage test device is used for power transformers, voltage transformers and other test objects. In addition to conducting external power frequency high voltage tests on the main insulation of fully insulated transformers, it is also necessary to conduct induction high voltage tests on the longitudinal insulation of transformers and the main insulation of semi insulated transformers.
Triple frequency generator, induced voltage triple frequency generator, triple frequency power generator, test triple frequency transformer device, triple frequency induction withstand voltage generator, triple frequency test transformer, triple frequency testerTriple frequency induction voltage tester, voltage transformer double frequency AC voltage tester, double frequency power generator, triple frequency induction voltage generator, triple frequency induction generator, triple frequency high voltage generator, triple frequency voltage generator, electronic triple frequency power generator
The third harmonic high voltage generator produced by our company is easy to operate and has reliable performance
◆ Can effectively meet the needs of transformer and transformer induction withstand voltage
Input voltage: three-phase 380V 50HZ
Output voltage: single-phase 0-300V/0-500V/0-1000V (continuously adjustable), frequency: 150HZ
Output capacity: 0-1000kvA, harmonic distortion:<1%
◆ Idle running time: ≤ 5 minutes
Duration of the test sample at rated voltage: 40 seconds
◆ Load characteristics: resistive, inductive, capacitive can all be used