The German WTW turbidity measuring instrument VisoTurb700IQ adopts the 90 degree dispersion method measurement principle, with built-in ultrasonic aut
Product details
GermanyWTWturbidity sensorVisoTurb 700IQ
feature
· *Advanced ultrasonic cleaning technology
· comply withEN ISO 7027
· Using precision optical components
· The optical lens is made of wear-resistant sapphire
· Electrode self checking function, good long-term stability
· Strictly and accurately calibrated before leaving the factory
· No wear parts
· Maintenance Province
GermanyWTWTurbidity measuring instrumentVisoTurb700Using the scattered light colorimetric method, in accordance withENISO 7027According to the standard regulations, the testing range is very wide, including turbidity measuring instrumentsVisoTurb 700from0to4,000FNUIt has an automatic range switching function, which reduces the resolution to 0.001FNU. Turbidity measuring instrumentVisoTurb700Equipped with advanced and reliable ultrasonic cleaning components, the probe can operate reliably for a long time with minimal maintenance. Turbidity measuring instrumentVisoTurb700Before leaving the factory, it undergoes strict multi-point testing and does not require calibration for on-site use. Principle of turbidity testing
Turbidity is caused by suspended particles in water, which diffuse and reflect back into the incident light. Typically, this is achieved through90The scattered light in that direction is used as the test signal, and the unit measured in this way is calledNTU. UseFormazineThe unit measured by the instrument after calibration with standard solution is calledFNUThis method is suitable for testing low to medium ranges, from0.01to4000 FNUThe scope. according toEN27027andISO7027Standard, adopted860nmInfrared light, as a light source, is not affected by the chromaticity of the sample.


Ultrasonic automatic cleaning system
There is an ultrasonic generator on the sensor, and as long as the sensor is connected to the system, high-frequency ultrasonic signals are generated, causing the optical lens to vibrate continuously with an amplitude of several micrometers. In the center of the lens, the amplitude is large. This can prevent any form of pollutants from accumulating on the lens, ensuring continuous and reliable operation. Some calcium salts will still adhere to the probe after a long time, forming dirt that is difficult to remove even with a brush or other cleaning agents, and can only be cleaned by acid washing. Ultrasonic vibration can also prevent bubbles from accumulating in the testing area and interfering with the test, as bubbles also scatter some light.

Comparison chart of 30 day ultrasonic cleaning and no cleaning

Comparison chart of 30 day ultrasonic cleaning and no cleaning
Technical SpecificationsVisoTurb 700 IQ
| |||
unit |
FNU; NTU; TEF |
mg/l SiO2; ppm SiO2 |
g/l TS |
Test range |
0.05 … 4000 FNU |
0.1 … 4000 mg/l SiO2 |
0.0001 … 400 g/l TS |
light source |
860 nm |
||
Typical Applications |
Discharge outlets for drinking water, surface water, and sewage treatment plants(SS<3g/l)
|
||
correction |
Original factory useFormazinecalibration
|
Original factory useSiO2calibration
|
User self calibration |
accuracy |
<1%(Range up to2000 FNU), in accordance withDIN 38402 part 51standard
|
||
repetitiveness |
< 0,015 %or≥ 0,006 FNU, in accordance withDIN ISO 5725or DIN 1319
|
||
resolution |
Automatic range switching
0.001 FNU … 1 FNU
0.001 mg/l … 0.01 g/l
0.001 mg/l … 0.1 g/l
|
||
Cleaning system |
Ultrasonic cleaning system |
||
SensCheck |
The electrode self diagnostic function outputs an alarm signal when the surface of the optical lens is contaminated or the cleaning system has a malfunction |
||
surrounding environment |
Operating Temperature0 … 60℃
Ultrasonic cleaning system:0 … 40 °C (overheat protection)
Storage temperature:-5 … 65℃
|
||
Mechanical Construction |
Optical lens: Sapphire
Electrode body:V4Astainless steel1.4571
Protection level:IP68
|
||
pressure resistance |
*Big10Ba (including sensor connection cable)
|
||
power consumption |
1.5 W |
||
size |
365×40 mm(Long)×Diameter, includingIQcableSACIQ
|
||
weight |
about990 g
|
||
warranty period |
Two years |
||
Digital universal transmitters can be selected from DIQ/S182 and MIQ/TC 2020