Low temperature shortwave infrared thermal imaging system PYRONINC 1600N endoscope
Temperature range: 1100~1800 ° C
PYROINC 1600N endoscope
Model abbreviation: PI1600NE
Low price high-temperature combustion chamber spy monitoring infrared thermal imager
Temperature measurement range: 1100~1800 ° C
Pixel: 1600x1200 (1.92 million pixels)
Wavelength: Near infrared (NIR) 0.8~1.1 micrometers
The main applications of endoscopic lenses are:
Measuring the temperature of all objects inside the furnace and imaging, suitable for monitoring the furnace walls of various kilns, monitoring the combustion chambers of various waste heat boilers, chemical furnaces, and recovery furnaces.
Main features
1. Ultra high image count, but still low price
2. Temperature measurement range 1100-1800 ° C
3. Measure furnace walls, refractory bricks, combustion conditions, etc., and measure the shape characteristics of flames
4. Electric focusing
5. Endoscopic lens
6. Refrigerated stainless steel probe, capable of withstanding high temperatures up to 1800 ° C in kiln environments
7. Remote access and maintenance of infrared thermal imagers
8. Portable automatic telescopic system ensures longevity
Technical data
model |
PYROINC 1600N endoscope |
spectral range |
0.8~1.1 µm |
Measuring range1 |
1100-1800 °C |
sensor |
Two dimensional Si CMOS array (1600 × 1200 pixels, equivalent to 1.92 million images) |
optical lens1 |
Aperture angle of 90 °× 72 °, measurement distance>1 m, electric focusing |
measurement error2 |
2% measurement value ° C |
NETD4 |
< 4K (1300°C, 25Hz) |
measurement frequency |
Internal 25Hz, optional: 15 Hz, 10Hz |
response time |
Internal 80 ms, optional: 2/measurement frequency |
communication interface |
Real time Ethernet (25Hz) with 2 electrically isolated digital inputs and outputs |
terminal |
HAN module (operating voltage, digital input and output, Ethernet) |
weight |
About 15 kg |
Auxiliary power supply |
12 V ~ 36 V DC, Generally 2.8~7.3 VA |
Shell form and size |
Stainless steel shell, length 1040mm, ∅ 60.3mm (air-cooled) |
Operating temperature of thermal imager |
- Infrared thermal imager for internal measurement of 10~55 ° C system |
Storage conditions |
-20 ° C~70 ° C, maximum relative humidity 95% |
software |