VIP member
Vacuum pump unit KCM620-V-01,02
Product specifications and model KCM620-V-01KCM620-V-02 Performance frequency Hz60 Design displacement ※ 1m3/h616 Reaching vacuum degree kPa100 or abo
Product details
Product Specifications
| Model number | KCM620-V-01 | KCM620-V-02 | |||
| performance | frequency | Hz | 60 | ||
| Design displacement ※ 1 | m3/h | 616 | |||
| Reaching vacuum level | kPa | Above 100 (below 1.3kPa (abs)) | |||
| Yunzhuan sound ※ 2 | dB | 71 (when reaching vacuum level) 75 (80kPa) |
|||
| Dimensions: Width x Depth x Height | mm | 710×1394×1642 | 710×1394×1822 | ||
| Product weight | kg | 770 | 800 | ||
| Exterior color | Dark Grey Mansell No. N3.0 | ||||
| Pipe connection diameter | 100A JIS 10K Flange | ||||
| Drive Type | belt transmission | ||||
| start method | Inverter start | ||||
| Electrical Characteristics | Power supply ※ 3 | V(Hz) | Three phase 200 (50/60), 220 (60) | ||
| Power ※ 4 | kW | 13.5 | |||
| Current ※ 4 | A | 41.0 | |||
| protective device | pump | Overcurrent relay setting value ※ 5 | A | 47.5 | |
| thermostatic switch | Open at 55 ℃ and close at 45 ℃ | ||||
| Cooling fan motor | overcurrent relay Set value ※ 5 |
A | 3.0 | ||
| Set up environment | Setting up a venue | indoor | |||
| Allowable ambient temperature ※ 6 | 5~40℃ | ||||
| Inhalation of gas | Room temperature: 5-40 ℃ 常湿: 65±20(JIS Z8703) Environment without corrosive/flammable/explosive gases Clean air without high temperature steam, condensation, and less dust |
||||
| Set the elevation of the venue to ※ 7 | Below 1000m | ||||
| Pollution level ※ 8 | Pollution level 3 (ordinary factory environment, etc.) | ||||
| Overvoltage classification ※ 8 | Category 3 (provided by fixed wiring equipment) | ||||
| Remarks | Theoretical value calculated based on volume. Please refer to the pressure flow line diagram for the actual flow rate. Actual measurement values at 200V-60Hz. The instantaneous fluctuation range of the power supply voltage should be within ± 10% of the rated voltage, and the allowable range for continuous fluctuation should be within ± 5% of the rated voltage. Actual measurement values at 80kPa and 200V-60Hz. The set value of the protection device built into the ESB (control unit). If the ambient temperature is around 5 ℃ during startup, high-frequency sounds may be produced, but this is not an abnormality and the sound will disappear in a short period of time. If the duration of high-frequency sound exceeds 30 minutes, please consult the salesperson. If you need to use it in places with an elevation exceeding 1000m, please consult our company. Please refer to IEC664-1 for reference. |
||||
Outline dimension drawing KCM620-V-01
Unit: mm

Outline dimension drawing KCM620-V-02
Unit: mm