German E+H sewage type flowmeter W500 4-channel electromagnetic flowmeter
German E+H Proline Promag W 500 electromagnetic flowmeter with 3-channel input/output split type transmitter, sensor anti-corrosion protection in accordance with EN ISO 12944 standard
The German E+H Proline Promag W 500 electromagnetic flowmeter is a specialized flowmeter for measuring hazardous areas in the water and wastewater industry. It is an ideal solution for direct underground installation or long-term underwater use. The innovative split type transmitter design ensures flexibility in installation and maximum operational safety under harsh operating conditions. Heartbeat Technology ensures compliance at all times and guarantees process safety.
advantage
Directly buried installation or long-term underwater use: certified sensors
Long term operation is safe and reliable: a sturdy and durable integral welded sensor
Energy saving flow measurement: No throttling components to ensure no pressure loss
Maintenance free: No movable parts
Provide complete process information and diagnostic information: allowing multiple users to customize input/output signal combinations and fieldbus communication
Reduce complexity and variability: Allow users to customize input/output functionality
Comes with verification function: Built in Heartbeat Technology
Application field
The bidirectional measurement principle is not affected by pressure, density, temperature, and viscosity
Specialized flow meters for demanding applications in the water and wastewater industry.
Instrument features
International Drinking Water Certification
IP68 (Type 6P, enclosure) protection level
Split type instrument with up to 3 inputs/outputs
Backlight display, touch key control, and WLAN access
Sensors and transmitters are connected through standard cables
Features and specifications
|
Measuring principle |
electromagnetic |
|
Product Title |
A split type transmitter with 3 inputs/outputs, with sensor anti-corrosion protection in accordance with EN ISO 12944 standard. Directly buried installation or long-term immersion in water for use. Specialized flow meters for demanding applications in the water and wastewater industry. |
|
Sensor characteristics |
Long term operation is safe and reliable: a sturdy and durable integral welded sensor. Energy saving flow measurement: There are no other devices inside the pipeline and no pressure loss. Maintenance free: No moving parts. Obtained international drinking water certification. The protection level is IP68 (Type 6P). |
|
Characteristics of transmitter |
Provide complete process and diagnostic information: multiple user customizable I/O interfaces and fieldbuses. Reduced complexity and variability: User defined I/O interfaces. Self verification: Heartbeat Technology. Split type instrument with up to 3 input/output channels. Backlight display, key operation, and WLAN access. |
|
Nominal caliber range |
DN 25...2000 (1...78") |
|
Material of liquid receiving components |
Lining: Polyurethane, Hard Rubber |
|
Electrode: 1.4435 (316L), Alloy C22 2.4602 (UNS N06022) alloy, tantalum |
|
|
Measure variables |
Volume flow rate, conductivity, mass flow rate |
|
Zd measurement error |
Volume flow rate (standard): ± 0.5% O.R. ± 1 mm/s (0.04 in/s) |
|
Volume flow rate (optional): ± 0.2% O.R. ± 2 mm/s (0.08 in/s) |
|
|
measurement range |
9 dm3/min...110 000 m3/h (2.5 gal/min...700 Mgal/d) |
|
Zd process pressure |
PN 40、Class 300、20K |
|
Medium temperature range |
Hard rubber lining: 0...+80 ° C (+32...+176 ° F) |
|
Polyurethane lining: -20...+50 ° C (-4...+122 ° F) |
|
|
Environmental temperature range |
Carbon steel flange: -10...+60 ° C (+14...+140 ° F) |
|
Stainless steel flange: -40...+60 ° C (-40...+140 ° F) |
|
|
Material of sensor housing |
DN 25... 300 (1... 12 "): Aluminum alloy AlSi10Mg coating |
|
DN 25... 2000 (1... 78 "): Carbon steel with protective paint coating |
|
|
Sensor junction box (standard): Aluminum alloy AlSi10Mg coating |
|
|
1.4409 CF3M316 sensor junction box (optional): polycarbonate |
|
|
Material of transmitter housing |
Aluminum alloy AlSi10Mg coating; 1.4409 (CF3M), similar to 316L; polycarbonate |
|
Protection level |
Integrated instrument: IP66/67, type 4X |
|
Split type sensor (standard): IP66/67, type 4X |
|
|
Split type sensor (optional): IP68, type 6P, with protective paint coating, compliant with EN ISO 12944 C5-M/Im1/Im2/Im3 anti-corrosion certification |
|
|
Display/Operation |
Four line backlit display, touch key operation (external operation) |
|
Set up on-site display units and debugging software |
|
|
output |
3-channel output: |
|
4... 20 mA HART (active/passive) |
|
|
4...20 mA WirelessHART |
|
|
4... 20 mA (active/passive) |
|
|
Pulse/frequency/switch output (active/passive) |
|
|
Dual pulse output (active/passive) |
|
|
relay output |
|
|
input |
Status input |
|
4... 20 mA input |
|
|
digital communication |
HART、PROFIBUS PA、FOUNDATION Fieldbus、Modbus RS485、Profinet、Ethernet/IP、OPC-UA |
|
power supply |
24 VDC |
|
100...230 VAC |
|
|
100... 230 VAC/24 VDC (non hazardous area) |
|
|
Explosion-proof certification |
ATEX、IECEx、cCSAus、INMETRO、NEPSI、EAC |
|
Product safety |
CE certification, C-tick certification, EAC certification |
|
Functional safety |
Functional safety follows the IEC 61508 standard and is allowed to be used in safety applications specified in the IEC 61511 standard |
|
Metrological certification and certificates |
Calibrate on the certification calibration device (compliant with ISO/IEC 17025 standard) NAMUR |
|
Heartbeat Technology meets traceability verification requirements and complies with ISO 9001:2008 standard section 7.6a (T ü V certification) |
|
|
Pressure certification and certification |
CRN |
|
Material Certificate |
3.1 Material Certificates |
|
Sanitary certification and certification |
ACS、KTW/W270、NSF 61、WRAS BS 6920 |